Charger Specifications - National Railway Supply ERB-C 12/201 Installation, Operation And Service Instructions

Shelf-mount solid state chargers
Table of Contents

Advertisement

16. CHARGER SPECIFICATIONS

Model
AC Input Voltage
AC Input Current (full power)
115VAC
230VAC
AC Input Frequency
AC Line Regulation
*indicates 2.00 volts/cell; all other 2.27
volts/cell (60 Hz) at rated current output
AC Fuses
DC Output Voltage Maximum
DC Output Current Maximum
DC Output Ripple
(2.0 volts / cell)
Power Factor
(2.0 volts / cell)
Power Factor
(2.23 volts/cell)
DC Output
Regulation
DC Output
Cord Length
Weight, Net
www.nationalrailwaysupply.com
ERB-C 12/201
115VAC (100-128) or 230VAC (200-256)
5.2 amps
2.6 amps
11.3% for 8 cells
19.5% for 7 cells
26.5% for 6 cells
34.7% for 5 cells
42.7% for 4 cells
46.5% for 3 cells
57.1% for 2 cells
58.2% for 1 cell
MDA 4 or equivalent
22.5 volts
20 amps
1.4 Vp-p
at 20 amps
.3 Vp-p
at 2 amps (2.27 v/cell)
20 amps
81.0 for 8 cells
76.0 for 7 cells
68.0 for 6 cells
62.0 for 5 cells
54.0 for 4 cells
57.0 for 3 cells
40.0 for 2 cells
34.0 for 1 cell
2 amps
- 24.0 for 8 cells
- 24.0 for 7 cells
- 21.0 for 6 cells
- 19.0 for 5 cells
- 17.0 for 4 cells
- 16.0 for 3 cells
- 14.0 for 2 cells
- 12.0 for 1 cell
Voltage:
1.0 - 20.0 volts + 0.5%
Current:
1.0 - 20.0 amps + 0.5%
< 60 ft. - 8 AWG
< 40 ft. – 10 AWG
26.2 lbs.
10
ERB-C 12/501
14.6 amps
7.8 amps
60 – 100 + 5% Hertz (single-phase)
10% *
MDA 12 or equivalent
22.5
50 amps
1.0 Vp-p
at 50 amps
.15 Vp-p
at 2 amps
Percentage for High Rate at:
50 amps
77.0 for 9 cells
70.0 for 8 cells
64.0 for 7 cells
57.0 for 6 cells
51.0 for 5 cells
Percentage for Low Rate at:
2 amps
- 24.0 for 9 cells
- 23.0 for 8 cells
- 22.0 for 7 cells *
- 21.0 for 6 cells
- 20.0 for 5 cells
* 2.0 volts/cell
Voltage:
1.0 - 20.0 volts + 0.5%
Current:
1.0 - 50.0 amps + 0.5%
< 15 ft. - 6 AWG
> 15 ft. - Heavier
42.2 lbs.
ERB-C 24/301
16.5 amps
8.25 amps
10% *
MDA 12 or equivalent
36.0 volts
30 amps
1.2 Vp-p
at 30 amps
.25 Vp-p
at 2 amps
30 amps
79.0 for 18 cells
73.0 for 16 cells
66.0 for 14 cells
58.0 for 12 cells
2 amps
- 68.0 for 18 cells
- 67.0 for 16 cells
- 66.0 for 14 cells
- 64.0 for 12 cells
Voltage:
10.0 - 36.0 volts + 0.5%
Current:
1.0 - 30.0 amps + 0.5%
< 20 ft. - 8 AWG
> 20 ft. - Heavier
44.3 lbs.
01434J

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Erb-c 12/501Erb-c 24/301

Table of Contents