In a class by itself DAWF0 and DAWS0 SERIES DRYERS D R Y E R I N S T A L L A T I O N M A N U A L " Laundrylux 461 Doughty Boulevard Inwood, NY 11096-0338 Doc. No. 112819 www.laundrylux.com...
Page 2
Retain This Manual in a Safe Place for Future Reference This product embodies advanced concepts in engineering, design, and safety. If this product is properly maintained, it will provide many years of safe, efficient, and trouble free operation. Only qualified technicians should service this equipment. OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment or specified in the installation manual included with the dryer.
WARNING WARNING Children should not be allowed to play on or near the dryer(s). Children should be Proposition 65 supervised if near dryer(s) in operation. Use of this product could expose you to substances Under no circumstances should the dryer door from fuel combustion that contain chemicals switch(es), lint door switch(es), or heat safety known to the State of California to cause cancer,...
Safety Precautions ___________________ WARNING WARNING Do not use heat for drying articles that contain plastic, foam, sponge rubber, or similarly textured rubber For your safety, the information in this manual must materials. Drying in a heated tumbler may damage be followed to minimize the risk of fire or explosion plastics or rubber and also may be a fire hazard.
Page 5
Use this dryer only for its intended purpose, drying fabrics. The “Cool Down” Cycle of tumble dryers should be used to reduce the temperature of the items. They should not be NOTES _____________________________________________________ removed from the tumble dryer or piled or stacked while hot. ____________________________________________________________ Fabric softeners or similar products should not be used in a tumble dryer to eliminate the effects of the static electricity,...
Specifications _____________________________________________________________________ MAXIMUM CAPACITY (DRY WEIGHT) 22 lb 9.98 kg TUMBLER DIAMETER 25-3/4” 65.41 cm TUMBLER DEPTH 24-3/4” 62.87 cm TUMBLER VOLUME 7-1/2 cu ft 212.38 L TUMBLER/DRIVE MOTOR 1/3 hp 0.25 kW BLOWER/FAN MOTOR BLOWER D RIVEN BY TUMBLER MOTOR DOOR OPENING (DIAMETER) 17-1/2”...
Page 7
Specifications _____________________________________________________________________ Top Control NOTE: The manufacturer reserves the right to make changes in specifications at any time without notice or obligation. 112819 - 1...
Page 8
Specifications _____________________________________________________________________ Bottom Control (Stackable) 112819 - 1...
Installation Procedures ______________ Unpacking / Setting Up ________________ Installation should be performed by competent professional Remove protective shipping material (i.e., plastic wrap and in accordance with local, state, and country codes. In the optional shipping box) from the dryer. absence of these codes, the installation must conform to applicable American National Standards: ANSI Z223.1- IMPORTANT: Dryer must be transported and handled in an LATEST EDITION (National Fuel Gas Code) or ANSI/NFPA...
Domestic Type I Remove the Crossover washer top cover and replace with the mounting adapter plate supplied with the dryer. Resecure the adapter plate using the two ST3.5 screws originally used to secure the washer cover. Do NOT use excessive force to A = 6-inches (15.24 cm) align the plate.
To compensate for the use of registers or louvers used over The ductwork should be laid out in such a way that the the openings, this area must be increased by approximately ductwork travels as directly as possible to the outdoors with 33%.
Horizontal Venting Multiple Dryer (Common) Venting When horizontal dryer venting is used, the length of the IMPORTANT: For extended ductwork runs, the cross- ductwork from the dryer to the outside exhaust outlet, must sectional area of the ductwork can only be increased to an not exceed 20 feet (6.10 meters).
Electrical Information ________________ LINE Electrical Requirements VOLTAGE TERM 60 Hz All electrical connections must be made by a properly licensed and competent electrician. This is to ensure that the electrical installation is adequate and conforms to local, state, and HIGH national regulations or codes of the country of origin.
Gas Information ______________________ For added personal safety, when possible, it is suggested that a separate ground wire (size per local codes) be It is your responsibility to have all plumbing connections, connected from the ground connection of the dryer to a materials, and workmanship conform to local and state grounded cold water pipe.
Heat Input / Gas Consumption/Orifice (Injector) Data Gas Specifications for Non-CE and Non-AGA Approved Dryers** Nominal Supply Gross Burner Orifice Orifice Size Heating Value Pressure Heat Input Pressure (Injector) Type Quantity B tu /ft in WC Btu/hr in WC Natural 1,000 26,000 6.0-12.0...
Page 16
Parts Required for Conversion: Description Unregulated Gas Conversion Kit** 140414 Regulated L.P. Gas Conversion Kit*** 140416 Burner Orifice (Injector) L.P. Conversion Label 114515 Refer to page 15 for orifice (injector) size. Required for unregulated propane or butane only. *** Required for regulated LPG or propane only. Instructions Disconnect electrical power to the dryer.
Reinstall the burner tube onto the burner base. There are two types of devices used to measure gas pressure. They are the spring/mechanical type gauge and the Select from the following three options, the conversion to be manometer. The use of the spring/mechanical type gauge is performed: not recommended because they are very easily damaged •...
Preoperational Test __________________ Preoperational Instructions __________ All dryers are thoroughly tested and inspected before leaving IMPORTANT: For more detailed information regarding the the factory. However, a preoperational test should be microprocessor controller (computer), refer to the performed before the dryer is publicly used. It is possible microprocessor user’s manual included with the dryer.
Service / Parts Information ___________ Weekly Clean lint accumulation from lint chamber, thermostat, and Service microprocessor temperature sensor area. Service must be performed by a qualified trained technician. If service is required, contact the reseller from whom the WARNING equipment was purchased. If the reseller cannot be contacted or is unknown, contact the Service Department for a reseller in your area.
____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ When contacting Laundrylux, the information on the data label ____________________________________________________________ is required to ensure proper service/parts assistance. The data label is located on the back of the machine. ____________________________________________________________ 1. Model Number – This describes the style of dryer and ____________________________________________________________ type of heat (gas or electric).