B. Chase Top
A metal chase top is required to seal the top of the chase
around the chimney pipe. The top should include a turn-
down and drip edge to prevent water from seeping into the
chase. Provide a 1/8 in. (3 mm) gap around the fl ue pipe
and slope the top downward away from the penetration. See
Figure 6.4.
•
All seams must be caulked to prevent leaks.
•
A chase installation must use a chase top. Chase tops
are available from your Heatilator dealer or may be fi eld
constructed.
•
Attach the chase top to the top of the chase.
Caulk
Figure 6.4
Chase Top Construction
24
Termination Cap
2 in. (51 mm) Collar
on Chase Top
Storm Collar
Slope Downward
Turn-down
Drip Edge
Chase
(Chimney)
.018 (26 ga) min.
Galvanized
Chase Top
Heatilator • ST42A US-CAN • 4012-039 Rev D • 11/07
C. Install the Termination Cap
Note: To protect against the effect of corrosion on those
parts exposed to the weather, the termination cap can be
painted with a rust-resistant paint.
WARNING
Fire Risk
•
The minimum overlap of cap to pipe
MUST be met or chimney may separate
from cap.
Separation allows sparks, heat and embers
to escape.
•
Install the chimney sections up through the chase
enclosure. When using a TR11/TR444 Round Termination
Cap, the uppermost top section of pipe must extend 6 in.
(152 mm) above the top of the fl ashing collar to allow
installation of the storm collar and termination cap. See
Figure 6.5.
Minimum 1-1/2 in. (38 mm) overlap of cap over pipe
6 in. (152mm) min.
Flashing Collar
Figure 6.5
Installing a TR11/TR444 Round Termination Cap
•
For installations utilizing a TR11T/TR442 Round
Telescoping Termination Cap, the uppermost chimney
section must be below the top of the chase top, but not
more than 14-1/2 in. (368 mm) below the top of the chase
top. Minimum overlap of chimney and termination cap
must be 1-1/2 in. (38 mm). See Figure 6.6.
Flashing Collar
Top of Pipe
Figure 6.6
Installing a TR11T/TR442 Round Telescoping Termina-
tion Cap
Storm Collar
2 in. (51 mm) min.
2 in. (51 mm) min. collar
Storm Collar
2 in. (51 mm) min.
14-1/2 in. (368mm) max.
1-1/2 in. (38 mm) min.
overlap