Download Print this page

Lux Products ELV4C Installation And Operating Instructions

Programmable heating thermostat

Advertisement

Quick Links

INSTALLATION AND

OPERATING INSTRUCTIONS

ELV4c
Heating Thermostat
Single Pole and Double Pole
Line Voltage
WARNING: Use Energizer
®
or DURACELL
®
Energizer
®
is a registered trademark of Eveready Battery Company, Inc.
DURACELL
®
is a registered trademark of The Gillette Company, Inc.
Mt. Laurel, New Jersey 08054, USA
http://www.luxproducts.com
Thank you for your confidence in our product. To obtain the best results
from your investment, please read these instructions and acquaint
yourself with your purchase.
COMPATIBILITY
This programmable thermostat is compatible with Single or Double pole,
120/240 VAC, line voltage electric heating systems up to 16 Amps. The
heating wattage rating is 1900 Watts (Resistive) for 120 VAC, and 3800
Watts (Resistive) for 240 VAC. This thermostat can also be used with
120/240 VAC line voltage Hydronic (hot water) heating systems with
motors up to 1/4 HP.
This thermostat cannot be used with: cooling systems, typical 24 volt
systems, or heat pump systems. Ask your dealer for other LUX
thermostats to control those systems.
NOTE: Disconnection Type: "TYPE 1B".
FEATURES
LCD Display
T
U
5 : 36
H
MORN
72
E
º
DAY
A
T
EVE
NIGHT
PM
DOWN
LUX
Speed Dial
®
SET
SET
WEEKDAY
WEEKDAY
PROGRAMS
PROGRAMS
HOLD
SET
RUN
NEXT
DAY/TIME
Battery
Compartment
SIMPLIFIED INSTRUCTIONS
TEMPORARY TEMPERA TURE
OVERRIDE
TO SET TIME & DA Y
• Press UP/DOWN to adjust set
• Rotate Dial to set
DA TE/TIME.
temperature.
• T o clear OVERRIDE press
• Press UP to change current
UP/DOWN until original set
day .
temperature appears or wait
for the start of the next period.
•Press NEXT .
•Press UP/DOWN to set
TEMPERA TURE HOLD
time.
• Press HOLD.
• Adjust temperature as desired
TO SET PROGRAMS
with UP/DOWN.
• Rotate Dial to SET
• T o clear , press HOLD again.
WEEKDAY
Rotate the dial to the RUN
PROGRAM or SET
position to close the door
WEEKEND PROGRAM.
• Press UP/DOWN to adjust
start time.
• Press NEXT .
• Press UP/DOWN to adjust
temperature.
• Press NEXT .
• Repeat as needed or rotate
dial to RUN to stop
programming.
• Heating Only
• Battery Free Memory Storage
• Armchair Programmable
• Temporary Temperature
• 3 Year Warranty
Override
• Temperature Hold
• On Screen Low Battery Indicator
• Attractive Design
• F/C Temperature Display
• 12/24 Hr Clock Display
• Exclusive LUX Speed Dial
®
• Adjustable Temperature Swing
• 5/2 Day Programming
• 4 Periods Per Day
INSTALLATION
Please read ALL of these instructions carefully before beginning
installation. Save them for future reference.
W A R N I N G
• This Thermostat is a line voltage (120/240 VAC) control. Do not
attempt to install it unless you are completely familiar with line-
voltage wiring. If improperly handled, there is a risk of electric shock
hazard which may cause serious injury or death.
• The thermostat is rated for normal full load current from a double 20A
circuit breaker or fuse block. Do not use on circuits with current
protection devices that are rated higher than 20 amps.
• Maximum load for this thermostat MUST NOT exceed 3800 Watts,
otherwise a potential fire hazard exists.
MOUNTING LOCATION:
Install a vertical, electrical switch box for mounting the thermostat
approximately 5 Feet (1.5 Meters) above the floor on an inside wall
where the thermostat will be exposed to average room temperature. The
use of a "deep" style switch box will make the installation easier by
providing more room for making the wiring connections. The thermostat
must be placed away from concealed warm or cold water pipes, air
ducts, or drafts from hallways, direct sunlight, fireplaces, or stairways in
order to sense room temperature properly. Do not place the thermostat
directly above any of the heating elements.
CAUTION
Turn off electricity to your heating system prior to
installing this thermostat, or servicing any part of
OFF
the system. Do not turn electricity back on until
installation is fully completed.
WIRING:
1. Disconnect power before removing your old thermostat (if applicable).
Double check that this thermostat is rated for the voltage and
amperage to be switched.
2. Remove the front portion of the thermostat by carefully pressing the
button at the bottom of the thermostat and swinging the body up and
away.
3. When replacing an old line voltage wall thermostat, remove it carefully
to avoid damage to the insulation on the wiring. Check the old
insulation for cracks, nicks, or fraying and apply certified electrical
tape where necessary to achieve adequate insulation, or replace the
wires in an approved fashion.
4. Use the diagrams shown in the "WIRE IDENTIFICATION AND WIRING
SCHEMATICS" section of this manual to ensure that the thermostat
connections are made to the proper wires for your installation.
5. Attach the wires together using the solder-less wire connectors
(provided), and be sure that all wire connectors are tight and secure.
NOTE:
Wiring performed must comply with all applicable national electrical
codes and local ordinances for your particular area.
6. Bend the solid conductors, and then push them and the wire
connectors into the electrical box carefully, providing enough
clearance behind the mounting screw locations. Secure the
thermostat base to the electrical box with the mounting screws.
7. Place the thermostat front portion onto the back plate by first catching
Programmable
the plastic tabs at the top, and then firmly pressing the bottom of the
thermostat towards the back plate to latch the halves together.
When you are finished performing your installation and setup
options, please remove the thin plastic film that is protecting the
52088
LCD display screen on the front of the thermostat. This plastic
may or may not be present, and is evident by the appearance of
Alkaline Batteries Only.
8. Install two new Energizer
before continuing further. Ensure that the batteries are installed in the
proper direction as per the markings shown in the battery tray. The
battery tray is located in the front of the thermostat, behind the door.
9. Now turn the supply power back on to the heating system.
On the thermostat screen, ensure that the Power Unit
Disconnected Indicator (shown at right) is not present on
the display screen. If it is, remove the front half and try
mating the front half to the back half again.
This thermostat is protected against normal static electric
discharges, however to minimize the risk of damaging the unit in
extremely dry weather, touch a grounded metal object before

SETUP OPTIONS

The settings, options, and components
listed in this section below are located
on the rear of the thermostat, on the
circuit board.
OPTION SWITCHES:
Temperature
There is a square box with 2 small
UP/DOWN
switches, located to the right side of the
buttons
circuit board. Each switch controls a
UP
different setting depending on the
position of the switch. The individual
HOLD, NEXT,
switches are labeled as 1 and 2, and
and RESET
there is a corresponding table printed
buttons
on the circuit board to show the
possible options for each of the two
RESET
switch positions.
HEAT / OFF
TEMPERATURE SCALE (Option Switch #1):
Power
This determines how the thermostat displays all temperatures on the
Switch
screen. Switch position OFF is F°, and ON is C°.
TIME FORMAT (Option Switch #2):
This determines how the thermostat displays the clock and all other
Quick
times on the screen. Switch position OFF is 12 HR, and ON is 24 HR.
Reference
Instructions
HARDWARE RESET:
The hardware reset is a push button that is located near the center of the
EL V4001
circuit board. This reset button is used by the thermostat to read the
position of the option switches. When either of the two option settings
above are changed, the hardware reset button must be pushed for the
change to be recognized. This can also be used if the thermostat is
exhibiting any erratic behavior. User temperature programs are not
erased when a hardware reset is performed, however you will have to set
the clock and day of the week.
FRONT PANEL ITEMS
SOFTWARE RESET:
The Software Reset is a small recessed push button that is located to the
right of the NEXT and HOLD buttons. This button can be pushed with a
pencil or the end of a paper clip. The software reset clears all of the
user temperature programs, and all other software preferences to their
default values. You should write down your heating program times and
temperatures prior to using the Software Reset.
PUSH BUTTONS:
There are four primary push buttons on the front
of the thermostat: The UP and DOWN arrow keys,
the NEXT button, and the HOLD button.
ROTARY DIAL:
The LUX Speed Dial
quickly navigate between the different
programming areas. This rotary dial has four
individual positions.
HEAT / OFF SWITCH:
This switch is located on the right side of the
power unit (back half of thermostat) as shown to
the right. In the winter, set the power switch to
HEAT to control your heating system. In the
spring, summer, and fall, set the switch to OFF if
you would like to prevent your heating system
from turning on.
OPERATING INSTRUCTIONS
SET DAY/TIME:
Rotate the dial to the SET DAY/TIME position. The day of the week will
start flashing on the display. With the day flashing, press the UP button,
once for each day, to advance to the desired day of the week. Press the
NEXT button; this should cause the time to start flashing and the day to
remain on steady. Using either the UP or DOWN buttons, adjust the
clock to the desired time. The clock digits will increment rapidly if either
the UP or DOWN buttons are held in the pressed position.
TEMPERATURE OVERRIDE:
A Temperature Override occurs in Run mode, anytime the user adjusts
the set temperature to a value other than what the stored program set
temperature is for that day and time. When the thermostat is in an
Override, the word "OVERRIDE" will appear in the bottom of the display
screen. The thermostat will maintain thermal control using this new set
temperature, until the start of the next program period time is reached.
At that time, the set temperature will return to the value stored in
memory for that new program period. To enter an Override, push either
the UP or DOWN button once and the set temperature will begin to flash.
Push either the UP or DOWN button to the desired set temperature value.
An Override may be cancelled by rotating the dial or by initiating a HOLD.
TEMPERATURE HOLD:
A Temperature Hold is similar to an override, but is used for maintaining
a constant set temperature under manual control, for a longer time
duration. A Hold is the simplest means to set and maintain a fixed
temperature. It allows you to set and maintain a fixed temperature
indefinitely, without concern for programming.
© 2 0 1 0 L U X P R O D U C T S C O R P O R A T I O N . A L L R I G H T S R E S E R V E D
NOTE:
fake digits appearing on the display screen.
®
or DURACELL
®
"AA" size alkaline batteries
NOTE:
touching your thermostat.
HARDWARE
RESET
BUTTON
THERMOSTAT CIRCUIT BOARD
®
provides an easy way to
A temperature Hold may be used for days, weeks, or even months at a
time. To enter a Hold, push the HOLD button once, and the word"HOLD"
will appear in the temperature portion of the screen, along with the
flashing set temperature. While the set temperature is flashing, push
either the UP or DOWN button to the new desired set temperature value.
To cancel a Hold, press and release the HOLD button once again, or
rotate the dial away from RUN.
ADVANCED FEATURES
SWING SETTING:
A thermostat works by turning your heating system on and off whenever
the room temperature varies from the set-point temperature. The
amount of this variation is called the "swing". Your system should cycle
on about 3 to 6 times per hour. A smaller swing number increases the
number of cycles per hour, so the room temperature is more precise and
constant. A larger swing number decreases the number of cycles per
hour, but saves energy in most cases. To change the Swing setting, turn
the dial to RUN mode. Hold down the NEXT button and push the HOLD
button once, then let go of both. A single number will appear on the
P
screen. Use the UP/DOWN buttons to change the number value between
1 and 9. Number 1 is the default setting. Press the NEXT button to
accept the setting and return to normal Run mode.
MINIMUM RUN TIME DELAY:
This is determined by the thermostat, and controls the minimum length
of time that the thermostat must remain with the Heat either On or Off,
before it will automatically switch to the alternate On or Off state. This
feature prevents rapid undesired cycling of the heating equipment. The
time amount for this delay is fixed at 5 minutes between on or off load
changes.
PROGRAMMING
For the two program types that are described below, this thermostat
OPTION
provides four independent periods per day for Heat mode, they are:
SWITCHES
ON
MORN, DAY, EVE, and NITE. Each period ends at the start time of the
1 2
following period. When you install batteries for the first time, or perform
a Software Reset, a default temperature program (shown below) is
inserted into all four of the program periods. You can use this default
SW
#1
#2
program, or alter any portion of it to suit your own preferences. When
F
12HR
C
24HR
setting the program items, the value that is flashing is the item that you
OPTION
can change at that time.
TABLE
PERIOD
MORN
DAY
EVE
NITE
SET WEEKDAY PROGRAM:
Rotate the dial to WEEKDAY PROGRAM. You will be programming all
five weekdays at the same time. The first period is MORN. Using the UP
and DOWN buttons, set the start time for this period, and then push the
NEXT button to proceed. Now set the desired set temperature for the
MORN period using the UP and DOWN buttons, and push NEXT to
proceed. Now set the start time and set temperature for the DAY period,
pushing NEXT after each to advance. Continue with these same steps to
set the start time and set temperature for the EVE, and NITE program
periods. When you are finished setting all four periods, you may
continue pushing the NEXT button through all four periods to review
your entries, or turn the dial to RUN if you are finished.
SET WEEKEND PROGRAM:
Turn the dial to WEEKEND PROGRAM. You will be programming both
Saturday and Sunday at the same time. You will begin with the start
time of the MORN period, and use the same procedures that were
performed while setting the Weekday Program periods, using the NEXT
button to advance through the values. Return the dial to the RUN
position when you are finished.
BATTERIES AND MAINTENANCE
The batteries should be replaced AT LEAST once per year, or sooner if
the LOW BATT battery symbol appears in the lower left portion of the
display screen as shown. To replace the batteries in the thermostat,
open the front door of the unit. The battery
compartment is located just below the rotary dial
and push buttons. Pull the battery compartment
out, starting with the top edge. Remove the used
batteries from the battery tray and discard
appropriately.
Install two new Energizer
®
or DURACELL
into the battery tray. Observe the polarity markings shown in the battery
compartment to ensure proper installation. When finished, re-install the
battery compartment by first seating the bottom into its alignment pins,
and pivoting the top in towards the thermostat to snap the latch back
into place.
TECHNICAL ASSISTANCE
If you have any problems installing or using this thermostat, please
carefully and thoroughly review the instruction manual. If you require
assistance, please contact our Technical Assistance Department at
856-234-8803 during regular business hours between 8:00AM and
4:30PM Eastern Standard Time, Monday through Friday. You can also
receive technical assistance online anytime day or night at
http://www.luxproducts.com. Our web site offers you answers to the
most common technical questions, and also permits you to email your
questions to our technical support staff at your convenience.
WARRANTY
Limited Warranty: If this unit fails because of defects in materials or
workmanship within three years of the date of original purchase, LUX
will, at its option, repair or replace it. This warranty does not cover
damage by accident, misuse, or failure to follow installation instructions.
Implied warranties are limited in duration to three years from the date of
original purchase. Some states do not allow limitations on how long an
implied warranty lasts, so the above limitation may not apply to you.
Please return malfunctioning or defective units to the location from
which the purchase was made, along with proof of purchase. Please
refer to "TECHNICAL ASSISTANCE" before returning thermostat.
Purchaser assumes all risks and liability for incidental and consequential
damage resulting from installation and use of this unit. Some states do
not allow the exclusion of incidental or consequential damages, so the
above exclusion may not apply to you. This warranty gives you specific
legal rights and you may also have other rights which vary from state to
state. Applicable in the U.S.A. and Canada only.
MERCURY WARNING AND RECYCLING NOTICE
Mercury is considered to be a hazardous material. If this product is
replacing a thermostat that contains mercury in a sealed tube,
contact your local waste management authority for instructions
regarding recycling and proper disposal. It may be unlawful in your
state to place it in the trash.
TIME / TEMPERATURE
6:00 AM 70 °F (21 °C)
8:00 AM 62 °F (17 °C)
6:00 PM 70 °F (21 °C)
10:00 PM 62 °F (17 °C)
LO BATT
®
, "AA" size alkaline batteries

Advertisement

loading

Summary of Contents for Lux Products ELV4C

  • Page 1: Operating Instructions

    If improperly handled, there is a risk of electric shock hazard which may cause serious injury or death. • The thermostat is rated for normal full load current from a double 20A circuit breaker or fuse block. Do not use on circuits with current protection devices that are rated higher than 20 amps.
  • Page 2 WIRING DIAGRAM NOTE: This Double Pole thermostat model may be used in either Single Pole, or Double Pole wiring configurations. Only the LINE 1 (IN) and LOAD 1 (OUT) terminals are switched during normal temperature cycling. If this thermostat is used in a Single Pole configuration, the unused L2 LINE (IN) and L2 LOAD (OUT) wire ends must be securely insulated using the additional wire connectors provided.