Advertisement

SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE
An French manual is available upon request. Order P/N 900094-00.
Ce manuel est disponible en francais, simplement en faire la demande. Numéro
de la pièce 900094-00.
• Hot! Do not touch! The glass and
surfaces of this appliance will be hot
during operation and will retain heat
for a while after shutting off the appli-
ance. Severe burns may result.
• Carefully supervise children in the
same room as appliance.
• If small children are present in the home, it is
recommended that this appliance be fitted with
an adjustable safety gate or barrier screen.
C
US
WARNING
Listed to standards:
ULC-S610 & UL-127
Report # 14-180
EPA Cert. No. 537
P900093-00
INSTALLATION AND

OPERATION INSTRUCTIONS

WCT4820WS
EPA Wood-Burning Fireplaces
P/N 900093-00 REV. A 04/2015
MODEL
WCT4820WS
This installation manual will enable you to obtain a safe, efficient and
dependable installation of your fireplace system. Please read and
understand these instructions before beginning your installation.
Do not alter or modify the fireplace or its components under any circum-
stances. Any modification or alteration of the fireplace system, including
but not limited to the fireplace, chimney components and accessories,
may void the warranty, listings and approvals of this system and could
result in an unsafe and potentially dangerous installation.
IHP wood-burning fireplaces are designed for use as a supplemental
heater. They are not intended for continuous use as a primary heat
source.
Fireplace, also for use in mobile or
manufactured homes with solid fuel only.
WARNING
• The fireplace cannot be operated without a door
or firescreen. Consult your dealer to select the
correct door or firescreen.
• Important! To assure proper alignment of glass
doors: Install this fireplace in a square and
plumb condition, using shims as necessary at
sides and/or bottom.
• Install the fireplace only as described in these
instructions.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WCT4820WS and is the answer not in the manual?

Questions and answers

Summary of Contents for Superior WCT4820WS

  • Page 1: Operation Instructions

    INSTALLATION AND OPERATION INSTRUCTIONS WCT4820WS EPA Wood-Burning Fireplaces P/N 900093-00 REV. A 04/2015 MODEL WCT4820WS This installation manual will enable you to obtain a safe, efficient and dependable installation of your fireplace system. Please read and understand these instructions before beginning your installation.
  • Page 2: Safety Rules And Specifications For Mobile Or Manufactured Home Installation

    IMPORTANT! GENERAL SAFETY WARNING WARNING PRECAUTIONS. READ AND UNDERSTAND THESE SAFETY Use care when selecting window Always ensure that the air inlet to RULES BEFORE YOUR FIRST FIRE. treatments for windows located the fireplace is free from debris near the fireplace. Avoid using and any other obstructions that combustible flowing window can block the entrance of air.
  • Page 3: Table Of Contents

    Not tested under EPA certification. If Fireplace Installation ......Page 8 installed, this appliance no longer quali- • The WCT4820WS fireplace is not intended Locating The WCT4820WS Fireplace Page 8 Framing, Facing And Mantel ....Page 9 for use with a gas log set. Do not use a fies for EPA certification.
  • Page 4: Operating The Fireplace

    Primary Air and Air Boost Controls shorter burning time. chimney. The combustion air control must be There is no flue damper in the WCT4820WS 3/4 closed and pushed in to close the air boost fireplace. As is common with air tight stoves, (Figure 1) .
  • Page 5: Refueling For Best Performance

    Smoke Detectors Recommended Since there are always several potential sources chimney height is twelve (12) feet (3.7 m) not The WCT4820WS fireplace will operate best if of fire in any home, we recommend installing including the fireplace height. The chimney attention is given to operating the unit with the smoke detectors.
  • Page 6: Maintaining Your Wct4820Ws Fireplace

    Dealing With a Chimney Fire Chimney Maintenance NOTE: The use of a firewood moisture meter is recommended to ensure the firewood contains Regular chimney maintenance and inspection Regular chimney inspection and maintenance less than 20% moisture. combined with proper operation will prevent can prevent chimney fires.
  • Page 7: Finish Door Casing Care

    Figure 4 - Door Installation or on the ground well away from The door must be installed only when the installation of the WCT4820WS fireplace is all combustible materials, pend- completed. All you have to do is fit the male ing final disposal.
  • Page 8: Glass Care - Replacement

    Glass Replacement cutting floor or roof joists (see fireplace dimen- and lay it on a clean unabrasive surface. To The glass used for the WCT4820WS fireplace sions Page 10). replace the gasket, first remove all of the old is a high temperature ceramic glass (1,400° F / gasket and gasket cement.
  • Page 9: Framing, Facing And Mantel

    Cover the insulation with Drywall panels around the fireplace. Hearth Extension Requirements The WCT4820WS fireplace may be installed 12” Max. directly on a combustible floor. The supplied (305mm) safety metal strip must be positioned as follows:...
  • Page 10: Fireplace And Framing Dimensions

    Corner Installation Back Wall of Chase/Enclosure Combustion OUTSIDE CHASE Including Finising Materials if any Air Kit 19-1/8” 20-1/2” K (allow space when framing) Rough Framing Face (Unfinished Shown) * Zero Clearance From Back Spacer to Wall FRAMING DIMENSIONS 36-3/8” 924 mm Combustible materials can NOT be used in the space directly above the fireplace.
  • Page 11: Insulated Chase Construction

    Insulate Joists Same As Ceiling Insulated Chase Construction Storm Collar Roof Support Flashing Draft Stops Attic Radiation Shield Floor Ceiling NOTE: It is recommended that the chase Firestop walls and floor be insulated in the same Wall manner, using the same insulation, as CTDT the rest of the building, below the attic.
  • Page 12: Hot Air Ducting Installation

    See Figures 14 and 15 45” Min. * The height of the louver must be measured (1143mm) from the base of the WCT4820WS fireplace to the middle point of the louver. To extend the double outlet system forward Non-Combustible of the WCT4820WS fireplace (not flush), it...
  • Page 13: Central Forced Air Kit Installation

    1. Remove the plates closing up the 8” dia. G) At that point, the flexible pipe can be attached the sides of the WCT4820WS fireplace allow holes on top of the fireplace. Then, cut to any air distribution grill. It is possible to the connection of insulated flexible pipe which the insulation in order to obtain two 8”...
  • Page 14: Outside Air Kit

    OUTSIDE AIR KIT - REqUIRED OUTSIDE CONNECTION During operation, the fireplace requires fresh air for combustion and draws air out of the house. It may starve other fuel burning appliances Aluminum Tape such as gas or oil furnaces. As well, exhaust blowers may compete for Outside air, causing negative pressure in the house, resulting in smoke entering Plastic Cover...
  • Page 15: Chimney System

    If interior installation is impossible, install an AC chimney enclosed in an insulated chase. 2. The fireplace model WCT4820WS may be installed only with Security Chimneys International Ltd 6” diameter chimney systems. 3. A chimney venting a fireplace shall not vent any other appliance.
  • Page 16: Chimney Installation Instructions

    CHIMNEY INSTALLATION INSTRUC- Attic Radiation Shield TIONS Attic Radiation ASHT / S2100 Shield HT6103+ / HT6000+ 1. Cut and frame the holes in the ceiling, floor Solid Packed Pipe * Flashing and roof where the chimney will pass (see Figure 22). Use a plumb-bob to line up the center of the holes.
  • Page 17: Offset Chimney Installation

    If penetrating a wall, use Minimum Chimney Height Using Elbows a wall radiation shield. Fireplace Model WCT4820WS 3. Use another elbow to turn the chimney Chimney Model ASHT / S2100+ / HT6103+ / HT6000+ / AC vertically. Lock it to the chimney. Fasten...
  • Page 18 Offset Dimensions Total Height Horizontal Offset Chimney Elbow Offset & One Length Between Elbows Two Lengths Between Elbows 6” Height 8” 12” 18” 24” 36” 48” 8” & 48” 12” & 48” 18” & 48” 24” & 48” 36” & 48” 48”...
  • Page 19: Angled Wall Radiation Shield

    ANGLED WALL RADIATION SHIELD (RSM+ and RSMI30) When traversing a combustible wall with the chimney at a 30º or 45º angle, an angled firestop or wall radiation shield must be installed. Only one is required. Support ACRS NOTE: 45º angle for Canada only ( RSMI45 Straps In cold climate locations (climates where temperatures will fall below 32°...
  • Page 20: Chimney Support Installation

    CHIMNEY SUPPORT INSTALLATION Universal Roof Support 18” (460 mm) 18” (460 mm) When installing a support, slightly lift the chimney system so the weight will lie on the support, not on the fireplace to reduce expansion noises. This support has three possible uses: 1.
  • Page 21: Masonry Application Instructions

    INSTALLATION INSTRUCTIONS FOR MASONRY APPLICATION Follow these steps: WARNING: Before starting the installation, the masonry chimney must 1. Position the fireplace in its location. Temporarily install the ASHT be inspected by a qualified chimney sweep. elbow on the top of the fireplace and, using a level, mark with an oval the location where the flue liner will enter the masonry chimney.
  • Page 22: Installation Accessories

    OPTIONAL INSTALLATION ACCESSORIES Installation Accessories Fireplace Kits Description Cat./Part No. Description Cat./Part No. Blower (heat activated on/off pre-wired), UZY5 UZY5 Door Kit (Required - Order Separately) Blower motor speed control (wall mount), VRUW VRUW Victorian Arch Shape Doors, Black, BUVBK F1855 BUCEBWZN Rigid firescreen...
  • Page 23: Replacement Parts

    SPECIFICATIONS REPLACEMENT PARTS LIST WCT4820WS Replacement Parts Cat. No. Model Description Cat./Part No. F1793 WCT4820WS Baffle refractory (2 pieces) PR-ISO2205 Back refractory PR-SR2203 EPA Estimated Model Emission Rate Heat Output Efficiency Right side refractory PR-SR2204D WCT4820WS 3.7 g/hr 10,442-27,746 btu/hr...
  • Page 24: Chimney Components Lists

    2125 Monterey, Laval, quebec 1-800-361-4909 (USA) Canada, H7L 3T6 1-800-667-3387 (Canada) securitychimneys.com Fireplace Model WCT4820WS - Approved Venting Components manu- Secure Temp ASHT 1” High Temp. Insulated Stainless Steel Chimney ® factured by Security Chimneys International™ only. 6” I.D and 8” O.D., Double-Wall Stainl. Steel, Listed to CAN/UCL-S604 and UL-103HT Description Part/Cat.
  • Page 25 SECURITY CHIMNEYS™ - PARTS AND COMPONENTS LISTS The components listed below must be ordered from Security Chimneys International™. Contact your Security Chimneys Distributor or Dealer for ordering information. Security Chimneys International Limited 450-973-9999 LL Chimney Lining System** ® Tubinox 2125 Monterey, Laval, quebec 1-800-361-4909 (USA) Rigid Stainless Steel Liner For Relining A Masonry Chimney, 6”...
  • Page 26 NOTES...
  • Page 27: Warranty

    THE WARRANTY Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior™ Brand wood burning fireplace ("Product") to be free from defects in materials and workmanship at the time of manufacture. The Product body, firebox and ceramic glass carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty against thermal breakage only.
  • Page 28: Product Reference Information

    WARRANTY Normally, all parts should be ordered through your IHP distributor or dealer. Parts will be shipped at prevailing prices at time of order. Your fireplace is covered by a limited warranty. Please read the warranty When ordering repair parts, always give the following information: to be familiar with its coverage.