Test Mode; Setting The Test Mode; Basic Operations Of The Test Mode - Sony MDS-JA20ES Service Manual

Minidisc deck
Hide thumbs Also See for MDS-JA20ES:
Table of Contents

Advertisement

4-1.
PRECAUTIONS FOR USE OF TEST MODE
• As loading related operations will be performed regardless of the test mode operations being performed, be sure to check that the disc
is stopped before setting and removing it.
Even if the § button is pressed while the disc is rotating during continuous playback, continuous recording, etc., the disc will not stop
rotating.
Therefore, it will be ejected while rotating.
Be sure to press the § button after pressing the
4-1-1. Recording laser emission mode and operating buttons
• Continuous recording mode (CREC MODE)
• Laser power check mode (LDPWR CHECK)
• Laser power adjustment mode (LDPWR ADJUST)
• Traverse (MO) check (EF MO CHECK)
• Traverse (MO) adjustment (EF MO ADJUST)
[     REC]
r
• When pressing the
4-2.

SETTING THE TEST MODE

The following are two methods of entering the test mode.
Procedure 1: While pressing the
[  ]
knob and p button.
When the test mode is set, "[Check]" will be displayed. Rotating the
four groups; ···N n Check N n Adjust N n Service N n Develop N n ···.
Procedure 2: While pressing the
When the test mode is set, "TEMP CHECK" will be displayed. By setting the test mode using this method, only the "Check"
group of method 1 can be executed.
Note: The tray is drawn out for a disc setting immediately when the test mode becomes active. Set a disc and push the tray by hand, so that the disc is
loaded automatically.
4-3.
EXITING THE TEST MODE
[REPEAT]
Press the
button. The disc is ejected when loaded, and "Standby" display blinks, and the STANDBY state is set.
4-4.

BASIC OPERATIONS OF THE TEST MODE

All operations are performed using the
The functions of these buttons are as follows.
Function name
[        AMS        ]
±
knob
Changes parameters and modes
[YES]
button
Proceeds onto the next step. Finalizes input.
[MENU/NO]
button
Returns to previous step. Stops operations.
SECTION 4

TEST MODE

[MENU/NO]
button.
[        AMS        ]
[  ]
knob and p button, connect the power plug to an outlet, and release the
±
[        AMS        ]
±
knob, connect the power plug to the outlet and release the
[        AMS        ]
±
knob,
Function
button and the rotation of disc is stopped.
[        AMS        ]
[YES]
[MENU/NO]
button, and
– 21 –
[        AMS        ]
±
knob switches between the following
[        AMS        ]
button.
±
±
knob.

Hide quick links: