5-3. SCHEMATIC DIAGRAM

• Refer to page 10 for IC Block Diagrams.
w
13
13
.
REC / BATT
Note:
• All capacitors are in µF unless otherwise noted. pF: µµF
50 WV or less are not indicated except for electrolytics
and tantalums.
• All resistors are in Ω and
1
/
W or less unless otherwise
4
specified.
• C : panel designation.
• A : B+ Line.
• H : adjustment for repair.
• Power voltage is dc 3 V and fed with regulated dc power
supply from battery terminal.
M-540V
• Voltage is dc with respect to ground under no-signal
condition.
no mark : PB
(
) : REC
• Voltages are taken with a VOM (Input impedance 10 MΩ).
Voltage variations may be noted due to normal produc-
tion tolerances.
• Signal path.
E
: PB
a
: REC

Hide quick links: