Microprocessor Control - Mitsubishi Electric MSZ-GF60VE Service Manual

Indoor unit
Hide thumbs Also See for MSZ-GF60VE:
Table of Contents

Advertisement

9

MICROPROCESSOR CONTROL

MSZ-GF60VE MSZ-GF71VE
WIRELESS REMOTE CONTROLLER
Operation display section
Temperature buttons
NOTE: Last setting will be stored after the unit is turned OFF with the remote controller. Indoor unit receives the signal of the
remote controller with beeps.
INDOOR UNIT DISPLAY SECTION
Operation Indicator lamp
The operation indicator at the right side of the indoor unit indicates the operation state.
•The following indication applies regardless of shape of the indication.
Indication
The unit is operating to
reach the set temperature
The room temperature is
approaching the set tem-
perature
Standby mode
(Only during multi system
operation)
9-1. COOL ( ) OPERATION
(1) Press OPERATE/STOP (ON/OFF) button.
OPERATION INDICATOR lamp of the indoor unit turns on with a beep tone.
(2) Select COOL mode with OPERATION SELECT button.
(3) Press TEMPERATURE buttons (TEMP
1. Coil frost prevention
The compressor operational frequency is controlled by the temperature of the indoor heat exchanger to prevent the coil
from frosting.
When the temperature of indoor heat exchanger becomes too low, the coil frost prevention mode works.
The indoor fan operates at the set speed and the compressor stops. This mode continues until the temperature of indoor
heat exchanger rises.
2. Low outside temperature operation
When the outside temperature is lower, low outside temperature operation starts, and the outdoor fan slows or stops.
3. Indoor fan speed control
When the thermostat turns OFF, the indoor fan stops running to reduce power consumption.
After that, the indoor fan stops for 60 seconds and then operates at Very Low for 10 seconds to sense accurate room
temperature. The indoor fan alternates ON and OFF at this interval while the thermostat is OFF.
When the room temperature rises and the thermostat is ON, the indoor fan starts running according to the settings on
the remote controller.
OBH634
Signal transmitting section
OPERATION SELECT button
ECONO COOL button
POWERFUL button
OPERATE/STOP
(ON/OFF) button
Indication of
remote controller
model is on back
Operation state
About 2°C or more away
from set temperature
About 1 to 2°C from set
temperature
or
button) to select the desired temperature. The setting range is 16 - 31°C.
i-save button
Room temperature
-
11
LONG button
WIDE VANE CONTROL button
FAN SPEED CONTROL button
VANE CONTROL button
TIME, TIMER set buttons
FORWARD button
BACKWARD button
WEEKLY TIMER
set button
RESET button
CLOCK SET button
Lighted
Blinking
Not lighted

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Msz-gf71ve

Table of Contents