Sony CDP-M400CS Service Manual page 23

Hide thumbs Also See for CDP-M400CS:
Table of Contents

Advertisement

SHIPMENT MODE
• This mode is used for setting the unit to the shipment state.
Do not execute it without a proper reason as it erases the
memory of the title memo recorded by the customer.
Procedure1:
With the power ON, while pressing the TIME button and MEGA
CONTROL button, press the 1/u button.
Rotate the DISC/ALBUM/CHARACTER dial, select "Ship Mode"
and press the dial. "-OFF-" is displayed and the standby mode is
automaticaly entered.
Procedure2:
With the power ON, while pressing the ARTIST MODE button
and H button, press the +100 button. "-OFF-" is displayed and
the standby mode is automatically entered.
DOOR POP UP AGING MODE
• This mode is used for performing aging of the CD pop up part
and door open/close.
It is used for checking if operations are performed normally.
Procedure1:
1. With the power ON, while pressing the TIME button and
MEGA CONTROL button, press the 1/u button.
2. Rotate the DISC/ALBUM/CHARACTER dial, select "CDM
Test"and press the dial.
3. Rotate the DISC/ALBUM/CHARACTER dial, select
"DoorPopup Aging" and press the dial.
4. Aging starts, and door open/close and up/down operations of
the pop up part are performed continuously.
5. To end this mode, press the 1/u button.
Procedure2:
1. With the power ON, while pressing the TOP ARTIST 3 button
and · button, press the +100 button.
2. Aging starts, and door open/close and up/down operations of
the pop up part are performed continuously.
3. To end the mode, press the 1/u button.
ALL LIT MODE
• This mode is used for lighting the whole fluorescent indicator
tubes and LEDs.
Procedure:
With the power ON, while pressing the TOP ARTIST4 and ·
buttons, press the +100 button.
Both the fluorescent indicator tubes and LEDs will light up
completely.
To end this mode, press the 1/u button.
MODEL NAME DISPLAY
• Model names can be displayed on the fluorescent indicator
tube for checking the microprocessor model setting, etc.
Procedure:
With the power ON, while pressing the TOP ARTIST6 and ·
buttons, press the +100 button.
The model name is displayed on the fluorescent indicator tube.
To end this mode, press the 1/u button.
SPRAY MODE
• This mode is used for the electrical adjustments.
Refer to the sedtion on Electrical Adjustment.
CDP-M400CS
23

Advertisement

Table of Contents
loading

Table of Contents