Download Print this page
Siemens Powers TH 192 S Technical Instructions
Siemens Powers TH 192 S Technical Instructions

Siemens Powers TH 192 S Technical Instructions

Single temperature room thermostat
Hide thumbs Also See for Powers TH 192 S:

Advertisement

Quick Links

1 2 0
Powers
Controls
TH 192 S Single Temperature Room
Thermostat
D D D D es
esc c c c r r r r i i i i p p p p t t t t i i i i o o o o n n n n
es
es
F F F F e e e e a a a a t t t t ur ur ur ures
es
es
es
O O O O p p p p t t t t i i i i o o o o n n n n a a a a l l l l D D D D e e e e s s s s i i i i gn
gn
gn
gn
F F F F e e e e a a a a t t t t ur ur ur ures
es
es
es
The TH 192 S thermostats are proportional single output, single set point, 1-pipe (low
air capacity) or 2-pipe (high air capacity) sensor controllers. Each thermostat includes a
wall mounting plate for installation in a variety of rough-in terminal boxes. A sensitive
bimetal responds to temperature change to modulate control air through a flapper
nozzle. One set point dial is provided. Air connections are made with 5/32" (4 mm) OD
plastic tubing, directly to the thermostat chassis for retrofit applications or with plug-in
adapters (provided with the TH 192 rough-in terminal box or optional accessories)
which slide into the wall mounting plate.
Direct and reverse acting models for one and two-pipe
Fahrenheit or Celsius set point dials
Highly sensitive bimetal thermostatic element
Field adjustable sensitivity with graduated scale
Integral field adjustable limit stops
Control pressure test port accessible without removing cover
Easily replaceable thermometer, set point dial, filters, and restrictor plate
Covers available for concealed or exposed thermometers and for either concealed,
key, or exposed knob adjustment and set point indication
Standard plastic thermostat covers provide desert beige or white finish
Fixed temperature limit stops meet government specifications
Competitor adapter mounting kits available
Metal covers available in standard configurations with a variety of finishes
All thermostat chassis available with optional 1/2" large set point adjustment knobs
Te Te Te Tec c c c h h h h n n n n i i i i c c c c a a a a l I l I l I l In n n n s s s s t t t t r r r r u u u u c c c c t t t t i i i i on on on on
Document No. 155-065P25
Rev. 1, July, 1999
POW ERS
Siemens Building Technologies, Inc.
TH 192-1
Landis Division

Advertisement

loading

Summary of Contents for Siemens Powers TH 192 S

  • Page 1 F F F F e e e e a a a a t t t t ur ur ur ures • Competitor adapter mounting kits available • Metal covers available in standard configurations with a variety of finishes • All thermostat chassis available with optional 1/2” large set point adjustment knobs Siemens Building Technologies, Inc. Landis Division...
  • Page 2 ..Page 2 Siemens Building Technologies, Inc. Landis Division...
  • Page 3 192-203K 192-222K 192-223K 1/2” Knob relay on Cover * One-pipe, 192-200K 192-201K 192-220K 192-221K non-relay * This feature requires a key set point adjustment cover (or key type cover). See Table 2. Siemens Building Technologies, Inc. Page 3 Landis Division...
  • Page 4 1/2” large set point adjustment knobs. 2. To order an optional thermostat cover finish, add the appropriate suffix letter listed in Table 3 to the end of the part number listed in Table 2. Page 4 Siemens Building Technologies, Inc. Landis Division...
  • Page 5 Two pipe 20 scim (5.5 ml/sec) Temperature Storage temperature -10 to 140°F (-23 to 60°C) Ambient operating temperature 40 to 140°F (4 to 60°C) Temperature response 0.1°F (0.06°C) Dial graduations 2°F (1°C) Siemens Building Technologies, Inc. Page 5 Landis Division...
  • Page 6 92 S S S S I I I I n n n n p p p p u u u u t t t t / / / / O O O O u u u u t t t t p p p p u u u u t t t t C C C C h h h h a a a a r r r r a a a a c c c c t t t t e e e e r r r r i i i i s s s s t t t t i i i i c c c c s s s s ..Page 6 Siemens Building Technologies, Inc. Landis Division...
  • Page 7 A A A A d d d d j j j j u u u u s s s s t t t t m m m m e e e e n n n n t t t t s s s s ..Siemens Building Technologies, Inc.
  • Page 8 70 and 80°F (21 and 27°C). using a hex key as shown. Allow thermostat to stand for about five minutes to adjust to the new setting. Page 8 Siemens Building Technologies, Inc. Landis Division...
  • Page 9 O O O O u u u u t t t t p p p p u u u u t t t t P P P P r r r r e e e e s s s s s s s s u u u u r r r r e e e e T T T T e e e e s s s s t t t t P P P P o o o o r r r r t t t t ..Siemens Building Technologies, Inc.
  • Page 10 5. Remove filters from existing connector and insert in new connector. Or, if filters are dirty, use restrictor replacement kit 192-321 to replace filters. 6. Use chassis tube connector replacement kit 192-525 to replace connector and mounting screws. Page 10 Siemens Building Technologies, Inc. Landis Division...
  • Page 11 20 scim (5.4 ml/sec) restrictors for 1-pipe systems (package of 5). (1/4 “, 6.4 mm, OD plastic barb unless noted.) Brass coupling, 1/8” NPT (1 only). 184-040 Coupling 184-116 184-113 Pre-piped dual tee for dual 1-pipe systems 184-130 Siemens Building Technologies, Inc. Page 11 Landis Division...
  • Page 12 Information in this publication is based on current specifications. The company reserves the right to make changes in specifications and models as design improvements are introduced. © 1999 Siemens Corporation S S S S i i i i e e e e m m m m en...