4)
Leakage of the refrigerant pipeline tested;
5)
Efficient drainpipe;
6)
Complete insulation protection;
7)
Correct earthing;
8)
Correct power supply;
9)
No obstacle outside the air inlet and outlet;
10) No air in the water pipeline and all valve opened;
11) Effective electric leakage protector;
12) Sufficient inlet water pressure( 0.15MPa)
4 Refrigerant figure
System Piping figure
Model : SWH-15/190TL
Compressor: GMCC PJ125G1C-4DZDE, R134a
TCO (Temp. Switch): when water Temp.
High Pressure Switch: switch OFF when 2.76MPa; switch ON when 2.07MPa;
Fan: Centrifugal type, 220V—240V/50Hz 3 Speeds;
E-heater: located in the mid of tank, 3000W/230VAC;
80, switch OFF, when water Temp.
Sanitary Water Heater Technical Manual
60, switch ON;