[ [ . RS-232C Command
RS-232C Command
[CMD ID DATA]
Cool
Mid
R Gain
Jg
Ja
G Gain
Jh
Jb
B Gain
Ji
Jc
R Offset
G Offset
B Offset
6-3. Adjustment of White Balance(manual)
Operate the Zero-calibration of the CA-100, then attach
O
sensor to PDP module surface when you adjust.
Manual adjustment is also possible by the following sequence.
O
(1) Enter '3.White-Pattern' by pressing ADJ KEY on the
Service Remote Control.
(2) Select "Test Pattern White" using Vol +/- Key and Execute
HEAT RUN at least 15 minutes.
(3) Receive the HDMI/DVI 720p 60Hz, Full size, 216 Gray
window pattern signal from AV Pattern Generator.
Input mode : HDMI/DVI
Baud rate = 115200bps
(4) Select the condition of screen Adjustment as 'Dynamic'.
(5) After attaching sensor to center of screen, select '2. White-
Balance' in 'Ez - Adjust' by pressing the ADJ KEY on the
Service R/C. Then enter adjustment mode by pressing the
G
Right KEY (
) .
a. In case color temperature is Cool.
B Gain = 192(lock)
R-Offset/ G-Offset/ B-Offset : 57/ 54/ 54 (lock)
Adjust the High Light by using R Gain/ G Gain.
b. In case color temperature is Medium
R Gain = 192 (lock)
R-Offset/ G-Offset/ B-Offset : 57/ 54/ 54 (lock)
Adjust the High Light by using G Gain/ B Gain.
c. In case color temperature is Warm
R Gain = 192 (lock)
R-Offset/ G-Offset/ B-Offset : 57/ 54/ 54 (lock)
Adjust the High Light by using G Gain/ B Gain.
(7) Adjust using Volume +/- KEY.
luminosity value : High Level : 216gray
a. Cool : X=0.278±0.002, Y=0.279±0.002
Color temperature : 11000°K±1000°K, dUV=-3dUV
b. Medium : X=0.287±0.002, Y=0.289±0.002
Color temperature : 9300°K±1000°K, dUV=-3dUV
c. Warm : X=0.315±0.002, Y=0.316±0.002
Color temperature : 6500°K±1000°K, dUV=-3dUV
(8) After adjustment is complete, move to Ez - Adjust screen
by pressing the ENTER(
mode by press ADJ KEY.
(Automatic Adjustment)
CENTER
(DEFAULT)(Hex)
MIN
Warm
Cool
Mid
Jg
00
C0
C0
Jh
00
C0
C0
Ji
00
C0
C0
00
39
39
00
36
36
36
36
00
A
) KEY. Then exit the adjustment
MAX
Warm
C0
ff
C0
ff
C0
ff
39
7f
36
7f
36
7f