York AFFINITY PV9 Technical Manual

Gas-fired condensing / high efficiency downflow/horizontal two stage variable speed furnaces

Advertisement

Quick Links

TECHNICAL GUIDE
AFFINITY
MODELS: PV9
GAS-FIRED
CONDENSING / HIGH EFFICIENCY
DOWNFLOW/HORIZONTAL
TWO STAGE VARIABLE SPEED FURNACES
NATURAL GAS
60 - 120 MBH INPUT
EFFICIENCY
RATING
CERTIFIED
Due to continuous product improvement,
specifications are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at
www.gamanet.org.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
ISO 9001
Certified Quality
Management System
DESCRIPTION
These Category IV, highly efficient, compact, condensing
type furnaces are designed for residential and commercial
installations in a basement, closet, alcove, recreation room or
garage where the ambient temperature is above 32°F, or
higher. They may be either side wall or thru-roof vented using
approved plastic type combustion air and vent piping. All
units are factory assembled, wired and tested to assure
dependable and economical installation and operation.
WARRANTY
Lifetime limited warranty on both heat exchangers to the orig-
inal purchaser; a 20-year limited warranty from original instal-
lation date to subsequent purchaser.
10-year warranty on the heat exchanger in commercial appli-
cations.
5-year limited parts warranty.
FEATURES
• Two stage heating operation includes:
- Two stage gas valve
- Two stage inducer operation
• Provides increased comfort level & very quiet unit opera-
tion
• Adjustable delay timer allows two stage operation with sin-
gle stage thermostat
• Compact, easy to install, ideal height 40" cabinet
• Blower-off delay for cooling SEER improvement.
• Easy to connect power/control wiring.
• Built-in, high level self diagnostics with fault code display.
• Low unit amp requirement for easy replacement application.
• Integrated control module for reliable, economical operation.
• May be installed as either two-pipe (sealed combustion) or
single pipe vent (using indoor combustion air)
• Top intake & vent connection allows installation in narrow
locations.
• Electronic Hot Surface Ignition saves fuel cost with increased
dependability and reliability.
• Induced combustion system with inshot main burners for
quiet, efficient operation.
• No special vent termination kit required.
• 100% shut off main gas valve for extra safety.
• 24V, 40 VA control transformer and blower relay supplied for
add-on cooling.
• Hi-tech tubular aluminized steel primary heat exchanger.
• Secondary (condensing) heat exchanger of 29-4C high-grade
stainless steel.
• Timed on, adjustable off blower capability for maximum com-
fort.
• Independent door removal for greater durabilty and ease of
access.
• Easy access from front of unit for cleaning, maintenance or
service.
• Protection from intake, exhaust or condensate blockage.
• Insulated blower compartment for quiet operation.
• 3-way transition facilitates fresh air piping.
• ClimaTraK comfort system allows dealer to customize comfort
settings based on regional location.
246785-YTG-B-0407

Advertisement

Table of Contents
loading

Summary of Contents for York AFFINITY PV9

  • Page 1 • Easy access from front of unit for cleaning, maintenance or Visit us on the web at www.york.com for the most service. up-to-date technical information. • Protection from intake, exhaust or condensate blockage.
  • Page 2: Electrical And Performance Data

    246785-YTG-B-0407 22-3/4 T-STAT WIRING 7/8” K.O. T-STAT WIRING 7/8” K.O. HORIZONTAL CONDENSATE DRAIN OPENING 1-3/4” 13-7/8 HORIZONTAL CONDENSATE DRAIN OPENING 1-3/4” HORIZONTAL CONDENSATE HORIZONTAL DRAIN OPENING 2” CONDENSATE DRAIN OPENING 1-3/4” JUNCTION BOX HOLE 7/8” 22-3/4 JUNCTION BOX 22-3/4 HOLE 7/8” GAS PIPE ENTRY 1-1/2”...
  • Page 3: Air Flow Data

    246785-YTG-B-0407 AIR FLOW DATA HIGH / LOW SPEED COOLING AND HEAT PUMP CFM - WITHOUT FILTERS PV9B12N060DH11 PV9B12N080DH11 Jumper Settings High High COOL Tap ADJ Tap 1329 1312 1133 1117 1226 1202 1039 1110 1084 PV9C16N080DH11 PV9C20N100DH11 Jumper Settings High High COOL Tap ADJ Tap*...
  • Page 4: Filter Sizes

    246785-YTG-B-0407 FILTER PERFORMANCE APPLYING FILTER PRESSURE DROP TO DETERMINE SYSTEM AIRFLOW The airflow capacity data published in the “Blower Perfor- mance” table listed above represents blower performance To determine the approximate airflow of the unit with a filter in WITHOUT filters. To determine the approximate blower per- place, follow the steps below: formance of the system, apply the filter drop value for the fil- Select the filter type.
  • Page 5 246785-YTG-B-0407 For additional connection diagrams for all UPG equipment refer to “Low Voltage System Wiring” document available online at www.upgnet.com in the Product Catalog Section. Thermostat Chart - AC Unitary Products Group...
  • Page 6 246785-YTG-B-0407 Thermostat Chart - HP Unitary Products Group...
  • Page 7 246785-YTG-B-0407 ACCESSORIES CONDENSATE NEUTRALIZER KIT - 1NK0301 Neutralizer cartidge has a 1/2" plastic tube fittings for installa- PROPANE (LP) CONVERSION KIT - tion in the drain line. Calcium carbonate refill media is also 1NP0347 - All units avaiable from the Source 1 Parts (p/n 026-30228-000). This accessory conversion kit may be used to convert natural HIGH ALTITUDE PRESSURE SWITCHES - gas (N) units for propane (LP) operation.
  • Page 8 Subject to change without notice. Printed in U.S.A. 246785-YTG-B-0407 Copyright © by York International Corp. 2007. All rights reserved. Supersedes: 246785/036-21636-002 Rev. A (1205) Unitary 5005 Norman Products York Group Drive 73069...

Table of Contents