1. Press the SCAN key to enter the auto scan menu directly. Or press the MENU key to display the main
menu on the monitor. Scroll to Auto Scan and push the Joystick to the right.
2. Select the" NUMBER" and set the desired number by pushing the Joystick left or right.
3. Select the "TITLE" and twist the Joystick to enter the title edit mode.
4. Twist the Joystick by changing the alphanumeric characters and move the next position. Or move down
to the character table and press CTRL or IRIS OPEN at the desired character then the cursor position
moves to the next position automatically. Push the Joystick left or right at the "ALL DELETE" field to delete
all characters. Push the Joystick left or right at the "EXIT" field to finish title edit menu.
5. Select "MODE" and "SPEED".
6. Select "START ANGLE". Hold down the CTRL key while selecting the start position using the Joystick.
Current panning position will be displayed. Release CTRL key to complete the selection of the start
position. Or Press IRIS Open then the "CTRL" displays. Move the desired position and the zoom position.
Press IRIS Close then the "CTRL" disappears. To adjust at the 0.1 degree interval, twist the Joystick at the
pan field and the tilt field. To adjust at the one zoom interval, twist the Joystick at the zoom field.
7. Select "END ANGLE." Hold down the CTRL key while moving the Joystick to select the end position. The
end position angle should be larger than start position. Release the CTRL key to complete the selection of
the end position. Or Press IRIS Open then the "CTRL" displays. Move the desired position and the zoom
position. Press IRIS Close then the "CTRL" disappears. To adjust at the 0.1 degree interval, twist the
Joystick at the pan field and the tilt field. To adjust at the one zoom interval, twist the Joystick at the zoom
field.
8. Set "SCAN DIR" to CCW or CW.
9. Select "SWAP". Set to ON, to exchange the start angle and the end angle.
10. Set "DWELL TIME".
11. Select Save and Exit and push the Joystick to the right or press IRIS Open. Press ESC or IRIS Close to
exit the program without saving.
Pressing the HOME key delete stored data at the angle field.
To set the position using the preset position:
a. Before entering the Auto Scan menu, select a preset position as a starting point for
Auto Scan.
Example: 2 + PRST and do step 1 to 4. In step 5, just press the Ctrl key at the start angle position, the
current position will be displayed as a start position.
b. Save and exit from the menu.
c. In normal mode, call a preset to be the end point of scan. Press 3 + PRST then press Scan key to enter
the Auto Scan menu. Move the cursor position to END ANGLE. Just press CTRL key at the end angle
position. Save and exit from the menu.
TITLE EDIT MENU
CTRL KEY
A01
$
A B C D E F G H I J
K L M N O P Q R S T
U V W X Y Z 0 1 2 3
4 5 6 7 8 9
ALL DELETE
EXIT (ESC TO EXIT)