Optical.adjustments - Sanyo PLC-XK3010 Service Manual

Hide thumbs Also See for PLC-XK3010:
Table of Contents

Advertisement

Optical Adjustments
Before taking optical adjustments below, remove the Cabinet Top following to the "Mechanical Disassembly" .
Remove the Main board and remove the AV panel. (Refer to Fig. 1)
Adjustments require a 2.0mm hex wrench and a slot screwdriver. When you adjust condenser lens (OUT) or Relay
lens (OUT) adjustment, you need to disconnect FPC cables of LCD panels on the main board.
Optical adjustment requires a 2.0mm hex wrench and a slot screwdriver.
Note: Please remove connector "K8000" and "K8JB" on the main borad, and do not remove other connectors, be-
cause the projector cannot turn on due to operate the power failure protection.
WArNING : uSe uV rAdIAtIoN eYe ANd SkIN Protec-
cAutIoN: to prevent suffer of uV radiation, those adjust-
ment must be completed within 25 minutes.
durING SerVIcING
Fig. 1
relay lens (out)
Adjustment
tIoN durING SerVIcING
contrast Adjustment
Main board
The AV panel is removed, and the
MAIN board is lifted.
condenser lens (out) Adjustment
-25-

Advertisement

Table of Contents
loading

Table of Contents