  • Page 1 Installation and User Guide Carbon Monoxide Alarm 10 Year Life Model W2-CO-10X...
  • Page 2 EN 50291-1:2010 EN 50291-2:2010 KM 551504 GN3231R3 W2-CO-10X Carbon Monoxide Alarm W2 module contained within product independently tested to RF standard ETSI EN 300 220-2 V2.3.2 (2010-02) by TRaC Global Ltd. A Sprue Brand Sprue Safety Products Ltd. Vanguard Centre, Coventry CV4 7EZ UK Technical Support: 0800 141 2561 / UK Textphone users: 18001 0800 141 2561 / EIRE dial 1-800 523171 Email: technicalsupport@sprue.com / Web: www.fireangel.co.uk...
  • Page 3: Table Of Contents

    CONTENTS Features ....4 Carbon Monoxide: How it Can Affect You and Your Family . 9 Positioning ... . 4 Product Indicators.
  • Page 4: Features

    FEATURES following advice, from 50292-2013 is applicable to all intended • Wi-Safe 2 technology, enabling wireless applications, there are special instructions interlinking between other at the end of this section relating to Wi-Safe 2 alarms. positioning in caravan holiday homes. •...
  • Page 5 far from the cooking appliances as possible Alarms located in sleeping rooms and and near to where the person sleeps. in rooms remote from a fuel-burning • If the appliance is in a room not normally appliance should be located relatively used (for example a boiler room), the alarm close to the breathing zone of the should be put just outside the room so...
  • Page 6: Installation

    INSTALLATION To place on a shelf: The base of the alarm has been designed DO: Ensure this alarm is installed by a to allow it to stand freely on a shelf. competent person who feels able to install IMPORTANT: When placing on a shelf, it according to the instructions.
  • Page 7: Wireless Interlink

    Install Alarm 1 as described earlier. wirelessly interlinked with up to 50 products within the Wi-Safe 2 product range. The W2-CO-10X is not designed to communicate with wireless alarms from other ranges or manufacturers. W2-CO-10X alarms need to be ‘learned- in’...
  • Page 8: Alarm Test

    the ‘learn-in’ button. The red LED will remain illuminated during this process. When the red LED goes out, release the button, it will then flash twice, followed by three further flashes to illustrate that the alarm has successfully been ‘un-learnt’ from the network.
  • Page 9: Sleep Easy Tm

    SLEEP EASY • Evacuate the property leaving the doors and windows open. Low battery warnings often start at night • Ring your gas or other fuel supplier on their or when it may be inconvenient to replace emergency number; keep the number in a your alarm.
  • Page 10 has no odour or taste and cannot be seen. Your CO alarm monitors the level of CO as Like oxygen, CO enters the body through parts per million (ppm) in the atmosphere the lungs during the normal breathing surrounding the alarm: process.
  • Page 11 COMMON SOURCES OF CO: • Oil and gas boilers • Portable generators • Oil or solid fuel cookers • Gas or paraffin heaters • Barbecues • Clogged chimneys • Wood or gas fireplaces • Cigarette smoke • Gas appliances • Any fossil fuel-burning appliance WARNING: This carbon monoxide alarm is not a combustible gas detector, nor a smoke detector.
  • Page 12: Product Indicators

    PRODUCT INDICATORS Mode Green LED Red LED Amber LED Chirp Flashes once per Normal Operation minute Flashes once every Four audible ‘chirps’ Alarm five seconds repeated Chirps once per Low battery / End of Flashes once per minute at the same sensor life minute time as the amber...
  • Page 13: Maintenance

    W2-CO-10X alarm, will last for the remainder of the period of the original warranty in respect of the alarm originally purchased – that is from the date of original purchase and not from the date of receipt of the replacement product.
  • Page 14 user guide. It does not cover events and conditions outside of Sprue Safety Products Ltd’s control, such as Acts of God (fire, severe weather etc.). It does not apply to retail stores, service centres or any distributors or agents. Sprue Safety Products Ltd will not recognise any changes to this warranty by third parties.
  • Page 16 Are you protected against toxic smoke from a house fire? For a full range of smoke alarms, fire blankets and extinguishers visit www.sprue.com...