Download Print this page

JVC AV-27D104 Service Manual page 22

Hide thumbs Also See for AV-27D104:

Advertisement

AV-27D104 AV-27D304
AV-27430 AV-27432
Measuring
Item
instrument
SUB COLOR
Signal
generator
Oscilloscope
Remote
control unit
No.
Setting item
S03
COLOR
Models
RA model
SA model
1-22 (No.52102)
Test point
TP-B
[1.V/C(S)]
TP-E
S03 : COLOR
[CRT SOCKET
PWB]
Y
G
R
(A)
C
W
B
M
Variable
Initial setting
range
0 127
W-B
Adjustment Voltage
+17V
+15V
Adjustment part
[ Method of adjustment without measuring instrument ]
(1) Receive the broadcast.
(2) Select <S03>(COLOR) of the 1.V/C(S).
(3) Set the initial setting value of the <S03> with the
[VOLUME (-/+)] key.
(4) If the color is not the best with the Initial setting
value, make fine adjustment of the <S03> until you
get the optimum color.
[ Method of adjustment using measuring instrument ]
(1) Receive the full field color bar signal (75% white).
(2) Select <S03>(COLOR) of the 1.V/C(S).
(3) Set the initial setting value of the <S03> with the
[VOLUME (-/+)] key.
(4) Connect the oscilloscope between TP-B and TP-E.
(-)
(5) Adjust <S03> and bring the value of (A) in the
illustration to the voltage given in the below table.
0V
(+)
value
64
Description

Advertisement