Behringer ULTRAGRAPH PRO FBQ1502 User Manual page 14

Ultra-musical 15-band and 31-band stereo graphic equalizer with fbq feedback detection system
Hide thumbs Also See for ULTRAGRAPH PRO FBQ1502:
Table of Contents

Advertisement

14
ULTRAGRAPH PRO FBQ1502/FBQ3102/FBQ6200 User Manual
FBQ6200
Audio Inputs
INPUTS
RF-filtered, servo-balanced XLR and
¼" TRS connectors
Impedance
40 kW balanced and unbalanced
Maximum input level
+21 dBu balanced and unbalanced
CMRR
typ. 40 dB, >55 dB @ 1 kHz
Audio Outputs
OUTPUTS
servo-balanced XLR and ¼" TRS connectors
SUBWOOFER OUT
balanced XLR connector,
level variable off to 0 dB
Crossover frequency
variable, 30 - 200 Hz
System Specifications
Frequency response
10 Hz to 30 kHz, +/-3 dB
S/N ratio
22 Hz to 22 kHz >94 dB @ +4 dBu
Distortion (THD)
typ. 0.006% @ +4 dBu, 1 kHz, Gain 1
Crosstalk
typ. -65 dB @ 1 kHz
Roll-Off Filtersection
Type
12 dB/oct., Butterworth
Input
variable (-15 dB to +15 dB)
Low Cut
variable (10 Hz to 400 Hz)
High Cut
variable (2.5 kHz to 30 kHz)
Graphic Equalizer
Type
analog 31-band equalizer
Frequency range
20 Hz to 20 kHz in 31 1/3-octave bands
(ISO frequencies)
Bandwidth
1/3 octave
Control range
+/-6 dB or +/-12 dB (switchable)
Limiter Section
Attack/Release
20 msec / 90 msec
Threshold
variable, -6 dB to +22 dB (off)
LED meter
Gain reduction 20/10/3/1 dB
behringer.com
Noise Generator
Type
Pink noise, level variable, off to 0 dBu,
LED level meter
-24/-12/-6/0 dB
Function Switches
FBQ
activates the FBQ Feedback Detection System
Audio In/Out
switch to bypass the equalizer functions
I/O Meter In/Out
switches the meter display from input to output
Range
shift of the maximum cut/boost range
for all 31/15 bands
Low Cut
Limiter
activates the limiter
Pink Noise
activates the noise generator
Subwoofer
activates the subwoofer output
Indicators
Input/output level
8-segment LED display:
-24/-18/-12/-6/0/+6/+12 dB/CLIP
Subwoofer
4-segment LED display:
-18/-12/0/+12 dB
Power Supply
Mains voltage
USA/Canada 120 V~, 60 Hz
Europe/U.K./Australia 230 V~, 50 Hz
Japan 100 V~, 50 - 60 Hz
general export model 120/230 V~, 50 - 60 Hz
Power consumption
35 W
Fuse
100 - 120 V~: T 630 mA H
200 - 240 V~: T 315 mA H
Mains connection
standard IEC receptacle
Dimensions/Weight
Dimensions (approx.)
5 ¼ x 19 x 5 7/8"
(H x W x D)
133.5 x 482.6 x 150 mm
Weight
approx. 5.95 lbs
approx. 2.70 kg
BEHRINGER continuously strives to assure the highest quality standards possible. Required modifications may
be implemented without prior notice. Technical data and the appearance of the unit may deviate from the above
values and/or illustrations.