9.3 Other technical data
TOTAL POWER:
Electric supply:
Appliance category:
Gas connection:
Appliance class:
9.4 Gas burners for NATURAL GAS G20 20 mbar
BURNER
Triple Crown
Semi-rapid
Auxiliary
9.5 Gas burners for LPG G30/G31 28-30/37 mbar
BURNER
Triple Crown 3,8
Semi-rapid
Auxiliary

10. ENERGY EFFICIENCY

10.1 Product information according to EU 66/2014
Model identification
Type of hob
Number of gas burners
Gas original:
Gas replacement:
220-240 V ~ 50/60 Hz
3 core flexible cable with non rewireable plug fitted with a 3 amp
cartridge fuse
II2H3+
R 1/2"
3
NORMAL POWER kW MINIMUM POWER
3,8
1,9
1,0
NORMAL
MINIMUM
POWER kW
POWER kW
1,4
1,9
0,45
1,0
0,33
G20 (2H) 20 mbar = 10,5 kW
G30 (3+) 28-30 mbar = 763 g/h
G31 (3+) 37 mbar = 750 g/h
kW
1,4
0,45
0,33
INJECTOR
NOMINAL GAS FLOW g/h
MARK 1/100
G30 28-30
mm
mbar
98
276
71
138
50
73
ENGLISH
17
INJECTOR MARK
1/100 mm
146
96
70
G31 37 mbar
271
136
71
HG753430NB