Sony CFD-V37 Service Manual page 10

Cd radio cassette-corder
Hide thumbs Also See for CFD-V37:
Table of Contents

Advertisement

CD SECTION
Notes on Check
1.
Perform the traverse check in the CD test mode.
After check, be sure to exit the test mode.
2.
Perform check in the order given.
3.
Use the disc (YEDS-18, Parts No. 3-702-101-01) only when
so indicated.
Before Check
Put the set into test mode and perform the following checks.
Repair if there are any problems.
• Sled Motor Check
Press + , = keys and confirm that the Optical pick-up moves
smoothly from the innermost to outermost circumference and back
smoothly and with no catching or abnormal noises.
(Cancellation of BTL mute)
+ : Optical pick-up moves to the outer circumference.
= : Optical pick-up moves to the inner circumference.
Focus Search Check
Press the CD ^ key. (Focus search operation is performed
1.
continuously.)
2.
Look at the Optical pick-up objective lens and confirm that it
moves up and down smoothly, with no catching or abnormal
noises.
Press p button.
3.
Confirm that focus search operation stops. If it does not, press
p button again longer.
How to Enter the Set into Test Mode
1.
Disconnect the AC power cord.
2.
Short-circuit the lands as shown on the CONTROL (1) board.
3.
Connect the AC power. (LCD 501 indicator blinks the test mode
pattern.)
How to Exit the Test Mode
Turn off the POWER.
[CONTROL (1) BOARD] – CONDUCTOR SIDE –
Test portion
Short : Test mode
Open : Normal mode
Jumper wire
— 10 —
E-F Balance Check
Adjustment Location : MAIN board
This check is to be done when the optical pick-up block is replaced.
Check Procedure:
1.
Connect the oscilloscope to test point TP (VC) and TP (TE) on
MAIN board.
2.
Put the set into test mode.
Optical pick-up setting to the center by + or = button
3.
pushing.
Insert disk (YEDS-18) and press ^ button.
4.
5.
Check that the oscilloscope traverse waveform is symmetrical,
as shown in the figure below.
6.
Release test mode after adjustment is completed.
C = 500mV ± 100mV
A = B
[MAIN BOARD] – CONDUCTOR SIDE –
TP(RF)
A
VOLT/DIV : 0.1V
0V
TIME/DIV : 1ms
B
C
TP(FE)
TP(VC)
TP(TE)
Osilloscope
(DC range)
TP(TE)
+
TP(VC)

Advertisement

Table of Contents
loading

Table of Contents