1.0 TECHNICAL SPECIFICATION and SERVICE HINTS
5.
Click YES to start the downloading. A status bar will
show the downloading progress of the firmware. Once
the downloading is complete the application will prompt
you to install the update onto your GoGear.
6.
Once the repair is complete a dialogue box will pop up;
click OK and unplug the GoGear from the computer.
IMPORTANT: All music & content of your micro
jukebox will be erased once the factory setting is
restored.
7.
Follow all screen instructions to complete the repair.
8.
The Device Manager will close automatically once the
success message is displayed. Close all opened
application and then unplug your micro jukebox.
9.
Once the GoGear micro jukebox is disconnected from
the computer, the display will show "Firmware
Upgrading" for a couple of seconds and then start up
as usual.

Service Hints

Re Rebuild database, firmware and
Microsoft (Plays For Sure) copy
protection key after replacement of
hard disk or PCBA
IMPORTANT: All devices having the hard disk or
PCBA replaced must have the firmware image,
database and the Plays For Sure key rebuilt before
returning to customers.
1.
Connect the GoGear to the power supply and the
computer with the combined charger and USB
cable.
2.
Reset the device by pressing and holding down
the Volume + and the power on/off slider switch
until the display turns off.
3.
While the device restart, press and hold the
volume – key until the Philips splash screen
disappear and showing the connection icon to put
the device in USB Mass Storage Device mode.
4.
The device will be listed as a new drive named
GOGEAR or MDJUKEBOX in Windows Explorer.
5.
Launch Windows Explorer and then quick format
the new drive to the file system FAT32.