Electro Detectors ZERIO PLUS EDA-Z5008 User Manual

Electro Detectors ZERIO PLUS EDA-Z5008 User Manual

Hide thumbs Also See for ZERIO PLUS EDA-Z5008:

Advertisement

ZERIO PLUS
EDA-Z5008, Z5020 & Z5100
USER MANUAL
ZPControlUserMan_r100
Revision 1.00

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ZERIO PLUS EDA-Z5008 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Electro Detectors ZERIO PLUS EDA-Z5008

  • Page 1 ZERIO PLUS EDA-Z5008, Z5020 & Z5100 USER MANUAL ZPControlUserMan_r100 Revision 1.00...
  • Page 2 EDA-Z5008, Z5020 & Z5100 – User Manual ZPControlUserMan_r100 _____________________________________________________________________________________________________ 0359 Electro Detectors Limited Electro House Edinburgh Way Harlow, Essex CM20 2EG, UK 0359 CPR 00226 DOP_EDA_Z5100 (covers all models) EN54-2:1997+A1:2006 EN54-4:1997+A1:2002+A2:2006 EN54-25:2008 Control and indicating equipment for fire detection and fire alarm systems for buildings Models: EDA-Z5008, EDA-Z5020, EDA-Z5100 Optional functions with requirements: Output to fire alarm devices...
  • Page 3: Revision History

    EDA-Z5008, Z5020 & Z5100 –User Manual ZPControlUserMan_r100 _____________________________________________________________________________________________________ Revision History V1.00 19/01/2015 User manual first release.
  • Page 4 EDA-Z5008, Z5020 & Z5100 – User Manual ZPControlUserMan_r100 _____________________________________________________________________________________________________ Introduction Electro Detectors has been manufacturing radio fire alarm systems since 1987 and with the introduction of a harmonised specification for Europe has complemented its range of products to meet EN54 Part 25. Based on the popular Zerio system, the updated Zerio Plus has been designed to be capable of handling 240 devices in 100 zones.
  • Page 5: Table Of Contents

    EDA-Z5008, Z5020 & Z5100 –User Manual ZPControlUserMan_r100 _____________________________________________________________________________________________________ Contents Front Panel Layout User Operation System Normal Fault Conditions Silence Buzzer Reset a Fault Alarm Conditions Silence the Alarm Re-sound the Sounders Reset the Alarm Access Levels Menu Operation Quick Menu Setup Menu Time and Date Disable/Enable Menu...
  • Page 6: Front Panel Layout

    EDA-Z5008, Z5020 & Z5100 – User Manual ZPControlUserMan_r100 _____________________________________________________________________________________________________ 1.0 - Front Panel Layout ① ② ③ ④ ⑤ ⑥ ① Fire LEDs If the panel goes into alarm, these LEDs will flash until the panel is reset. ② Zone Alarm LEDs In a fire condition, the appropriate zone LED will illuminate.
  • Page 7 EDA-Z5008, Z5020 & Z5100 –User Manual ZPControlUserMan_r100 _____________________________________________________________________________________________________ ④ Fault LEDs Common Fault Device or panel has a fault. See main display for details. This LED will remain lit until the panel has been reset. System Fault Fault that affects system performance. See main display for details. Sounder Flt/Disable If the LED is flashing, there is a fault with one or more sounders.
  • Page 8: User Operation

    EDA-Z5008, Z5020 & Z5100 – User Manual ZPControlUserMan_r100 _____________________________________________________________________________________________________ 2.0 - User Operation 2.1 - System Normal In normal operation the screen will show either the date and time, Tuesday or the supplier/service contact details. The unit can also be 01-01-2013 configured to alternate between the two.
  • Page 9: Silence The Alarm

    EDA-Z5008, Z5020 & Z5100 –User Manual ZPControlUserMan_r100 _____________________________________________________________________________________________________ 2.6 - Silence the Alarm When it is certain that it is safe to return to the building the Silence Alarm button should be pressed. The user will then be prompted to enter a valid user access code using the navigation keys. Up to 30 seconds should then be allowed for all sounders to silence.
  • Page 10: Menu Operation

    EDA-Z5008, Z5020 & Z5100 – User Manual ZPControlUserMan_r100 _____________________________________________________________________________________________________ 3.0 - Menu Operation To enter the menu system, press Menu. This will display an overview of any alarms, faults, disablements or tests that are currently active, along with an option to access the Main Menu. The options available on the main menu and sub-menus will be dependent on the access code entered and its corresponding access level.
  • Page 11: Setup Menu

    EDA-Z5008, Z5020 & Z5100 –User Manual ZPControlUserMan_r100 _____________________________________________________________________________________________________ 4.0 - Setup Menu 4.1 - Changing the system Time and Date – all access levels 1.Main Menu>>1.Setup>>1.Time & Date To change the time and date settings use the ← and → keys to Time: 12:39:00 Date: 01-01-2013 navigate to the value, and the ↑...
  • Page 12 EDA-Z5008, Z5020 & Z5100 – User Manual ZPControlUserMan_r100 _____________________________________________________________________________________________________ Disable Panel Inputs – all access levels 1.Main Menu>>2.Disable/Enable>>1.Disable>>3.Panel Input The two monitored inputs can each be disabled for a period of time specified by the user, dependent on their access level. All access levels can disable an input for a period of 1 to 96 hours. A commissioning user can disable an input indefinitely by selecting a time of ‘00’...
  • Page 13 EDA-Z5008, Z5020 & Z5100 –User Manual ZPControlUserMan_r100 _____________________________________________________________________________________________________ Enable a Zone – all access levels 1.Main Menu>>2.Disable/Enable>>2.Enable>>1.Zone To enable a previously disabled zone, select it using the ↑ or ↓ keys and press Enter. To enable more zones press Enter, or Cancel to exit. If all zones have been enabled ‘No Zones to enable’ will be displayed.
  • Page 14: Test Mode

    EDA-Z5008, Z5020 & Z5100 – User Manual ZPControlUserMan_r100 _____________________________________________________________________________________________________ 6.0 - Test Mode Test mode allows a system to be tested with minimal disruption to the occupants of a building. When a zone is placed into test mode the engineer can choose to disable sounders, actuators or any output devices.
  • Page 15: Maintenance

    EDA-Z5008, Z5020 & Z5100 –User Manual ZPControlUserMan_r100 _____________________________________________________________________________________________________ 6.3 - Lamp/Buzzer Test – advanced, service and commissioning users 1.Main Menu>>3.Test Mode>>3.Lamp/Buzzer Test This option will illuminate all the panels LEDs in sequence, to check they are working properly. The panel buzzer will also sound. A quick lamp test can be performed from any screen by holding down the Menu button for 2 seconds.
  • Page 16 EDA-Z5008FS 8 Zone Flush Mounted Wired Remote Display (Stainless Steel) EDA-Z5008SS 8 Zone Surface Mounted Wired Remote Display (Stainless Steel) EDA-Z5008SZ 8 Zone Standard Enclosure Wired Remote Display EDA-Z5000 Survey Kit Electro-Detectors Limited Electro House, Edinburgh Way, Harlow, Essex, CM20 2EG Email: eda@electrodetectors.co.uk...