49. Status check (Command: s v)
Check the current signal of the product.
Transmission
[s][v][ ][Set ID][ ][Data][ ][FF][Cr]
Data 02: Checks whether there is a signal
05: Checks whether luminance sensors 1 and 2 work properly.
06: Currently used luminance sensor
07: Checks whether the Top, Bottom, and Main temperature
sensors are functioning normally.
08: The temperature of each temperature sensor when the
monitor set was last powered off.
09: Fan Speed
Acknowledgement
[v][ ][Set ID][ ][OK/NG][Data][Data1][x]
Data:
If the value is 02,
Data1
00: Signal absent
01: Signal present
Data:
If the value is 05,
Data1
00: All sensors normal
01: BLU sensor 1 normal, BLU sensor 2 down
02: BLU sensor 1 down, BLU sensor 2 normal
03: All sensors down
Data:
If the value is 06,
00: Luminance sensor 1 currently used
01: Luminance sensor 2 currently used
Data:
If the value is 07,
Data1
00: All temperature sensors are faulty.
01: Top normal, Bottom faulty, Main faulty
02: Top faulty, Bottom normal, Main faulty
03: Top normal, Bottom normal, Main faulty
04: Top faulty, Bottom faulty, Main normal
05: Top normal, Bottom faulty, Main normal
06: Top faulty, Bottom normal, Main normal
07: All temperature sensors are normal
Data:
If the value is 08,
Acknowledgement
[v][ ][SetID][ ][OK/NG][Data][Data1][Data2][Data3][x]
Data1
The temperature of the Top sensor when the
monitor set is last powered off.
Data2
The temperature of the Bottom sensor when the
monitor set is last powered off.
Data3
The temperature of the Main sensor when the
monitor set is last powered off.
Data:
if the value is 09,
Acknowledgement
[v][ ][SetID][ ][OK/NG][Data][Data1][Data2][x]
Data1
00-ff: The upper 1-byte of the fan speed
Data2
00-ff: The lower 1-byte of the fan speed
Fan speed: 0 to 2008 in hexadecimal and 0 to 8200 in decimal
** Depending on the model, this feature may not be supported.
50. Speakers (Command: d v)
Sets the speakers feature.
Transmission
[d][v][ ][Set ID][ ][Data][Cr]
Data
00: Off
01: On
Acknowledgement
[v][ ][Set ID][ ][OK/NG][Data][x]
51. Daylight Saving Time (Command: s d)
Sets the Daylight Saving Time feature.
Transmission
[s][d][ ][Set ID] [ ][Data1] [ ][Data2] [ ][Data3] [ ]
[Data4] [ ][Data5] [Cr]
Data1
00: Off (Data2~5: FFH)
01: Start time
02: End time
Data2
01 to 0C: January to December
Data3
01 to 06: Weeks 1 to 6
* The maximum value of [Data3] may vary depending on the
date.
Data4
00 to 06 (Sunday to Saturday)
Data5
00 to17: 00th to 23th hour
* To read the start/end times, enter FFH in [Data2] through
[Data5].
(Ex. 1: sd 01 01 ff ff ff ff - Checks the start time.
Ex. 2: sd 01 02 ff ff ff ff - Checks the end time.)
* This feature is only available when Clock 1 (year/month/day)
and Clock 2 (hour/minute/second) are set.
Acknowledgement
[d][ ][Set ID][ ][OK/NG] [Data1][Data2][Data3]
[Data3][Data4][Data5][x]
** Depending on the model, this feature may not be supported.
52. Wake On Lan (Command: f w)
Selects whether to turn on/off Wake On Lan.
Transmission
[f ][w][ ][Set ID][ ][Data][Cr]
Data
00: Wake On Lan On
01: Wake On Lan Off
Acknowledgement
[w][ ][Set ID][ ][OK/NG][Data][x]
** Depending on the model, this feature may not be supported.