FIREPLACE INSTALLATION
Connection of the stovepipe directly into
the existing masonry chimney over the
fireplace opening is the only approved
method. This installation performs bet-
ter, yielding easy to clean and inspect
for creosote. Before beginning this type
of installation plan carefully; a high de-
gree of skill is required to insure safety.
An entry port for the stovepipe must be
cut through the chimney with minimum
damage to the fire clay liner. Some
involved measurements may be required
to locate the flue liner exactly. Before
cutting, take time to mark the size and
position of the entry port. Position the
entry port so that at least 8 inches of the
flue liner remains below the port.
Keep in mind that mantels and
combustible trim around the fireplace
must have adequate clearances from
the heater and stovepipe or must be
protected in an approved manner. Also,
be sure to leave at least 24" clearance
between the top of the stovepipe and
the combustible ceiling or other com-
bustibles. Placing the center of the entry
port 2 feet below the ceiling will insure
proper clearance for 6 inch, 8 inch, and
10 inch stovepipes. Next, install a fire
clay (at least 5/8 in. thick) or metal
thimble, being sure that the thimble is
flush with the inner flue lining. Secure
the thimble in place with refractory mor-
tar. The thimble should be surrounded
on all sides with 8 inches of brickwork
(solid masonry units) or 24 inches of
stone.
Install the stovepipe as far as possible
into the thimble, but not past the inside
of the flue lining. There should be a
small airspace (approximately 1/2 inch)
between the stovepipe and thimble,
allowing for expansion of the stove-
pipe. Seal this airspace with high-tem-
perature caulking or ceramic wool. Fi-
nally, be sure to wire the damper closed
and apply the same sealant you used at
the stovepipe and thimble junction.
Do not use the Type B installation (not
illustrated in this manual), that is, vent-
ing up through the fireplace opening,
regardless of whether the fireplace
opening is closed.
MASONRY CHIMNEY have several
positive attributes: If properly built, they
are
quite
durable,
and
homeowners consider them more at-
tractive perhaps than a non-enclosed
factory built chimney.
And, if the chimney is located within the
confines of the house (that is, not at-
tached to an exterior wall), its mass
alone will store heat longer and con-
tinue to release the heat long after the
fire has died. Masonry chimneys have
many disadvantages though.
Masonry chimneys constructed on an
exterior wall are exposed to cold out-
door temperatures, promoting greater
heater loss, higher accumulations of
creosote, and reduced draft which leads
to poorer heater or furnace perfor-
mance.
Concrete block chimneys (when not
protected by a brick veneer) are inher-
ently unsafe, result in poor draft, and are
subject to rapid deterioration. They do
not meet code and are not recom-
mended.
8
AUTOMATIC COAL BURNING CIRCULATOR HEATER
KEY NO. PART NO.
1
2
most
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17

REPAIR PARTS

MODEL NUMBER 2847

(SEE PAGE 18)

REPAIR PARTS LIST

DESCRIPTION
89062
Door Knob
83005
10-24x1/2" Machine Screw
83033
8-32x1/4" PH Screw
83093
Spring Latch
83244
10-24 Kep Nut
67968
Cabinet Door Frame
86191
Thermostat Linkage Adjuster
85381C
Control Panel Plate
89142
Thermostat Knob
67725
Cabinet Front
67967
Cabinet Left Side
24240
Flue Collar Ring
68350
Cabinet Top
67743
Thermostat Assembly
68505
Cabinet Back
89065
Door Hinge
67969
Cabinet Door
17
QTY.
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1

Advertisement

Table of Contents
loading

Table of Contents