5-2. PTC
Poor starting or no
operating of the
Compressor.
First, separate the PTC from the
Compressor and check the voltage
between NO 5 and 6 in the PTC
with a multitester or Wheatstone
Bridge.
Separate the OLP from the
Compressor and check
resistance value between two
terminals of OLP with Tester.
Observation value is
220~240V/50Hz :
The value is 0.
The value is
.
Check other electric
YES
components.
NO
Replace OLP.
- 16 -
Check another
Normal
electric
components.
Replace the PTC.
Abnormal
Abnormal
Replace the PTC.