CONNECTING THE MAINS CABLE
– Remove the two screws securing the
cover plate A behind the cooker.
– Remove the screw C from the cable
clamp.
– Insert the mains cable (type H05RR-F)
of minimum 6 mm
cable protector P.
– Connect the phase and earth cables
to the mains terminal connection
block B.
N
L
– Refit the cable clamp so that it
clamps the outer sleeving of the
cable.
– Refit the cover plate A.
Brown
(Live)
C
Fig. 10.1
2
section into the
EARTH
NEUTRAL
LIVE
TECHNICAL DATA
230 V AC - 50 Hz
Top conventional oven
– Top element
– Bottom element
– Grill element
Bottom fan oven
– Fan element
Vitroceramic hob
– Front left
– Back left
– Back right
– Front right
Maximum power rating
– Top oven
– Bottom oven
Oven lamp
300 °C, miniature edison screw
Fan motor
Maximum usable power
(diversity not applied)
L N
Blue
(Neutral)
P
0.70 kW
1.10 kW
2.10 kW
2.50 kW
1.70 kW
1.20 kW
2.10 kW
1.20 kW
2.10 kW
2.50 kW
0.015 kW
0.025 kW
10.875 kW