1. Connect the monitor cable to the VIDEO connector on the workstation
and to the monitor.
2. Be sure the monitor power switch is off and connect the monitor
AC power cable to the VAC power output connector on the workstation.
3. Connect an AC power cable to the VAC IN connector on the workstation
and to the 100 - 125 VAC or 220 - 240 VAC, 50 - 60 Hz power source.
4. Connect an AC power cable to the VAC IN connector on the multiplexer
and to the 100 - 125 VAC or 220 - 240 VAC, 50 - 60 Hz power source.
NOTE The SIP-150 Sonar Image Processor is autosensing and does not
require special switch settings for 110 VAC or 220 VAC operation.
The following connections are factory installed; however, should they be
disconnected, reconnect them as follows:
1. Connect the keyboard to the KEYBOARD and MOUSE connectors.
2. Connect DATA IN on the workstation to DATA OUT on the multiplexer.
3. Connect CLOCK IN on the workstation to CLOCK OUT on the
multiplexer.
4. Connect TELEM on the workstation to TELEM on the multiplexer.
The following connections are optional:
1. Connect any external SCSI storage devices to the SCSI connector on
the workstation.
2. Connect the printer cable to the PRINTER connector on the workstation.
3. Connect the navigation output from the shipboard navigation system to
NAV on the workstation.
4. If an external source is to provide the responder key, connect the
source's responder key output to RESP KEY IN on the digital multiplexer.
5. If an external source is to provide the sonar key, connect the source's
key output to EXT KEY IN on the multiplexer.
6. If an external source is to be keyed by the sonar key, connect the
source's key input to KEY OUT on the multiplexer.
SECTION 3 Setup and Deployment
Processor Hardware Connections
3-9