LCD panel
Type NR.
: QD17EL0709
Number of Pixels.
: 1280 (H) x1024 (V)
Physical Size.
: 358.5(w)*296.5(h)*17.5(d) mm
Pixel Pitch.
: 0.264 mm x 0.264 mm
Color pixel arrangement. : RGB vertical stripes
Support Color.
: 16.2M colors
Display Mode.
: Normally White
Backlight.
: CCFL edge light system
Active area. (WXH).
: 337.9 x 270.3 mm (17" diagonal)
Viewing Angle (CR>=10).: Vertical 125 degree, Horizontal 140
degree (Typ.)
Contrast ratio.
: 500:1
White luminance.
: 260nits (Typ.)
Horizontal scan
: 30 - 83 KHz
Vertical scan
: 56 - 76 Hz
Main Voltage
: AC 90 - 135 Vrms and 170 - 264 Vrms,
50/60 2 Hz
Power consumption
: 45W Max.
Operating < 35W (typical), Standby < 1W.
DC power switch off < 1W.
Power cord length
: 1.5M
Power cord type
: 3 lead with earth plug
Power indicator
: LED (ON: green, Standby: amber)
Auto power saving
: EPA, Nutek, VESA, DPMS (for analog),
DMPM (for digital according to DDWG
standard for DVI rev.1.0)
Display mode
:Multi-modes
Horizontal scanning
Sync polarity
:Positive or negative
Scanning frequency
:30K - 83 KHz
Vertical scanning
Sync polarity
:Positive or negative
Scanning frequency
:56 - 76 Hz
Pedestal.
: Detachable
Tilt angle.: -5 to 35
Swivel rotation: 125
Pin Assignment
Pin No.
Assignment
Red video input
1
2
Green video input
3
Blue video input
4
GND
Cable detect
5
Red video GND
6
Green video GND
7
8
Blue video GND
Input DVI-D connector pin
Technical Data - 170B6
Pin No.
Assignment
9
DDC +3.3V OR +5V
10
GND
11
GND
12
Serial data line (SDA)
H-sync
13
V-sync
14
15
Data clock line (SCL)
Pin No.
1
T.M.D.S. data2-
2
T.M.D.S. data2+
3
T.M.D.S. data2 shield
4
No Connect
5
No Connect
6
DDC clock
7
DDC data
8
No Connect
9
T.M.D.S. data1-
10
T.M.D.S. data1+
11
T.M.D.S. data1 shield
12
No Connect
13
No Connect
14
+5V Power
15
Ground (for +5V) - Cable detect
16
Hot plug detect
17
T.M.D.S. data0-
18
T.M.D.S. data0+
19
T.M.D.S. data0 shield
20
No Connect
21
No Connect
22
T.M.D.S clock shield
23
T.M.D.S. clock+
24
T.M.D.S. clock-
Environmental conditions
Operating
Temperature Range
5°C to 40°C
Humidity Range
20 % to 80%
Altitude Range
0 to 12000 feet
Storage
Temperature Range
-20°C to 60°C
Humidity Range
5 % to 95%
Altitude Range
0 to 30000 feet
Note: recommended at 5 to 35°C, humidity less than 60%.