GENERAL

1.1

Document Purpose

This document provides installation and specification information
on Westell's AWC‐TMAV‐850‐FB 850 MHz Full Band Tower
Mounted Amplifier (TMA). A Westell AWC‐TMAV‐850‐FB
TMA is shown in Figure 1. See Table 1 for ordering information.
1.2
Document Status
Whenever this document is updated, the reason will be stated in
this paragraph.
‐ NOTE ‐
Hereafter, the AWC‐TMAV‐850‐FB Tower Mounted Amplifier may
be referred to as the "TMA."
1.3
Product Purpose & Description
Westell's TMA's are cost­effective tools to extend cell site cover­
age and improve cell site capacity by conditioning and
amplifying the user‐endpoint uplink signal in an LTE radio ac­
cess network. Westell's TMAs can be used in any application
which requires improved receiver sensitivity of the BTS/eN­
odeB.
1.4

Product Mounting Location

The TMA is typically installed on a cell tower, close to the an­
tenna. See Paragraph 3.4 for mounting steps and Figure 6 for
dimensions.
1.5

Product Features

Features of the TMA are shown in the following list.
S
Advanced, balanced LNA design with variable gain capability
S
Low noise figure, return loss, and bypass insertion loss
S
Compact size
S
Heavy‐duty top and bottom mounting brackets with various
mounting holes to accept mounting bolts/screws and
mounting straps or bands
S
Two, female, 7/16 DIN connectors at the bottom of the unit;
one for antenna connection and one for BTS
S
Weather rating of IP67 (temperature range of ‐40_ to +65_C)
2

FUNCTIONAL DESCRIPTION

The TMA includes the following functional blocks, as shown in
Figure 2.
2.1
Control, Bias & Alarm Electronics
This block includes the control processor, AISG modem, and
lightning protection.
1312I1RA
‐ Installation Guide ‐
AWC‐TMAV‐850‐FB Tower Mounted Amplifier
E
Copyright 2013 Westell, Inc. All rights reserved.
030‐300302 Rev A, December 2013
Front View
Figure 1.
Tower Mounted Amplifier (TMA) Unit
2.2
Pre­LNA Rx BPF
This is the pre­LNA (Low Noise Amplifier) band pass filter.
This filter conditions the uplink signal from the antenna before
the LNA.
2.3

Balanced Low Noise Amplifier

This is the amplifier of the TMA and includes the bypass cir­
cuitry.
2.4
Post­LNA Rx BPF
This is the post­LNA band pass filter. This filter conditions the
uplink signal to the eNodeB.
2.5

Tx BPF

This is the transmit band pass filter. This filter conditions the du­
plexed downlink signal from the eNodeB to the antenna.
Control, Bias &
Alarm Electronics
Balanced Low
Noise Amplifier

Pre-LNA Rx BPF

RF Bypass
& Switches
ANTENNA
Figure 2.
Section AWC‐TMV‐850‐301
Equipment Issue 1
Rear View
Lightning
Protection
Post-LNA
Rx BPF
Bias-T
Tx BPF
BTS
Block Diagram
Page 1 of 6

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AWC?TMAV?850?FB and is the answer not in the manual?

Questions and answers

Summary of Contents for Westell AWC?TMAV?850?FB

  • Page 1: Installation Guide

    Hereafter, the AWC‐TMAV‐850‐FB Tower Mounted Amplifier may be referred to as the “TMA.” Product Purpose & Description Westell's TMA's are cost­effective tools to extend cell site cover­ Figure 1. Tower Mounted Amplifier (TMA) Unit age and improve cell site capacity by conditioning and amplifying the user‐endpoint uplink signal in an LTE radio ac­...
  • Page 2 Risk of electric shock. Differential voltages of up to 260V can exist 3.2.2 Powered from a Westell AISG Controller using CIM on telecommunications lines. When power is from an AISG Controller (such as a Westell AISG‐RM3 controller or an AISG‐CNTRL‐A controller kit), CAUTION ‐ STATIC‐SENSITIVE follow the steps below.
  • Page 3 1. Gather tools and equipment. The following tools may be shipping box and inspect it for any damage (report needed to mount the kit. damages to the shipping company and to Westell). Standard installation tools and hardware including 3. Remove the covers. Remove the plastic covers that protect...
  • Page 4 ‐ TL9000 RECYCLING NOTE ‐ ate the feeder cable that routes from the CIM/eNodeB. Westell recommends that its products be recycled at the end of their Connect the feeder cable to the female, 7/16, DIN connect­ product life. For Westell products that have reached their product or on the bottom of the TMA labeled “BTS.”...
  • Page 5 Variable Gain, 850 MHz, Full Band, Tower Mounted Amplifier Dimensions (H x W x D) 12.2” x 6.6” x 4.5” (including connectors & brackets) Westell sells a complete line of TMAs. Call Westell for further information. Weight 13.75 lbs Table 1. Ordering and Option Information Color Off­white...
  • Page 6 Section AWC‐TMV‐850‐301 030‐300302 Rev. A FRONT SIDE 4.12" 11.483" 8.972" 6.656" 1.57" 3.51" 1.57" 4.497" 0.695" BOTTOM 4.54" REAR VIEW REAR VIEW OF TOP BRACKET 6.656" 5.889" ISOMETRIC VIEW OF TOP .385 1.78" 1" 1.1" 1" 1.395" .385 BRACKET .4" .5"...