AXIS P3367–V Fixed Dome Network Camera
Technical Specifications

Connectors

I/O Connector
4-pin terminal block
For an example diagram, see Connection Diagrams on page 66.
Function
0 V DC (-)
DC output
Digital input
Digital output
Audio Connector
3.5 mm audio connectors
(stereo)
Audio Input
Audio Output
Pin
Notes
1
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
3
Connect to pin 1 to activate, or leave floating (unconnected)
to deactivate
4
Connected to pin 1 when activated, floating (unconnected)
when deactivated. If used with an inductive load, e.g. a relay,
a diode must be connected in parallel with the load, for
protection against voltage transients.
1 Tip
Microphone/Line in
Line out (mono)
3
2
1
2 Ring
65
1
2 3 4
Specifications
0 V DC
3.3 V DC
Max load = 50 mA
0 to max 40 V DC
0 to max 40 V DC, open drain,
100 mA
3 Sleeve
Ground
Ground