Millivolt Control Lighting Instructions - Monessen Hearth VWF18NA Installation And Operating Instructions Manual

Table of Contents

Advertisement

Millivolt CONTROL LIGHTING INSTRUCTIONS

The Millivolt control does not come preassembled with an on/off switch so that it
may be customized for the specific application with a wall switch, remote, etc. A
switch/remote must be connected to enable the burner to light.
1. STOP! Read the safety information label.
2. Make sure the manual shutoff valve is fully open.
3. Turn gas control knob clockwise
4. Wait (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas,
STOP!
5. From "OFF" position, turn the gas control knob counterclockwise
in control knob for 5 seconds.
6. With the control knob pushed in, light pilot with match.
7. Continue pushing the control knob in for a further 60 seconds to prevent the flame detector from shutting
off the gas while the probe is warming up. Release the control knob.
8. Turn gas control knob counterclockwise
9. After the pilot has been lit for one minute, the burners can be turned on. Turn the ON/OFF switch to "ON"
position.
10. If the gas logs will not operate, follow the instructions To Turn Off Gas To Heater and call your service
technician or gas supplier.
Figure 154 - Pilot
1. Turn control knob clockwise
2. If applicable: Turn ON/OFF switch to OFF position.
27D7300
OPERATING INSTRUCTIONS FOR MVVK KITS
to the "OFF" position, and turn ON/OFF switch to "OFF" position.
O N
Figure 155 - Control Knob
TO TURN OFF GAS TO HEATER
to OFF position to completely shut off the heater.
to the "ON" position.
O F
F
to "PILOT" position. Push
Figure 156 - On/Off Switch