2. The SERVICE indicator will still be illuminated until the trouble is restored.
3. Enter and hold down [7] key for 2 seconds.
4. The SERVICE and KEYLOCK indicators will slow flash and keypad audible indicator will
sound 2 beeps.
5. One or more ZONE indicators will turn ON to indicate the troubles occur.
6. Press [#] key to exit and keypad audible indicator will sound 2 beeps.
ZONE 1 indicator
ZONE 2 indicator
ZONE 3 indicator
ZONE 4 indicator
ZONE 5 indicator
ZONE 6 indicator
ZONE 7 indicator
Remark: Zone 1, 2, 3 and 4 indicators will only be extinguished after the troubles are restored.
Zone 5, 6 and 7 indicators will be extinguished when they are viewed once.

VIEW ALARM MEMORY

1. The system alarm memory will store the most recent alarm condition. An alarm condition
will cause the MEMORY indicator to slow flash.
2. The MEMORY indicator will extinguish once the user enters VIEW ALARM MEMORY
mode.
3. Enter and hold down [8] key for 2 seconds.
4. The MEMORY indicator will turn ON and keypad audible indicator will sound 2 beeps.
5. One or more ZONE indicators will turn ON to indicate the zones that cause the most recent
alarm.
6. Press [#] key to exit and keypad audible indicator will sound 2 beeps.

CHIME MODE

The chime mode allows user to monitor nominated zones while the system is disarmed. The
audible indicator will sound briefly when the nominated zone is violated – the siren will NOT sound.
If you wish to know there is someone enters or exits the front door, the keypad will beep once when
the door is opened provided the zone is a chime zone.
(Press and hold down for 2 seconds)
1. Press and hold down [9] key for 2 seconds.
AC Loss
Real Time Clock Loss
Siren Fail
Battery Low Voltage
Telephone Line/GSM CMS Reporting Fail
Telephone Line/GSM Personal Reporting Fail
Telephone Line Connection Fail
[8]
(Press and hold down for 2 seconds)
[9]
+ [ZONE NUMBERS] + [#]