Advertisement

Quick Links

TABLE OF CONTENTS

1. INTRODUCTION.............................................................................................
2. TESTING.........................................................................................................................
3. LIMITATIONS............................................................................................. ...
4. WARNINGS...................................................................................................
5. GLOSSARY...................................................................................................
6. UNDERSTAND YOUR KEYPAD INDICATORS.....................................................
7. SUMMARY OF OPERATION.............................................................................
8. TELEPHONY CONTROL DIAGRAM.................................................................... 8
9. USER PROGRAMMING SUMMARY ...................................................................
10. ARMING THE SYSTEM....................................................................................
11. DISARMING THE SYSTEM...............................................................................
12. TURN ON/OFF AUTOMATION POINT................................................................. 22
13. BYPASS ZONE...............................................................................................
14. UN-BYPASS ZONE.......................................................................................... 23
15. VIEW SYSTEM TROUBLE.................................................................................
16. VIEW ALARM MEMORY...................................................................................
17. CHIME MODE.................................................................................................
18. EMERGENCY SITUATION................................................................................
19. PARTITIONING THE SYSTEM...........................................................................
20. ARMING A PARTITIONED SYSTEM...................................................................
21. PARTITION DISARMING............................................................................... ...
22. USER PROGARMMING MODE.......................................................................... 36
23. EXIT USER PROGRAMMING MODE..................................................................
25. PROGRAM SYSTEM TIMER.......................................................................... ...
26. PROGRAM PARTITION 1 AUTO ARM TIMER......................................................
27. PROGRAM PARTITION 1 AUTO DISARM TIMER.................................................
28. PROGRAM PARTITION 2 AUTO ARM TIMER......................................................
29. PROGRAM PARTITION 2 AUTO DISARM TIMER.................................................
32. PROGRAM PERSONAL TELEPHONE NUMBER 1/2/3/4.........................................
33. PROGRAM SYSTEM DATE........................................................................... ...
35. TESTING THE SYSTEM................................................................................ ...
36. SYSTEM INFORMATION.................................................................................
V16 Plus USER MANUAL
1
2
2
2
2
3
4
6
9
16
20
22
24
25
25
26
28
28
35
37
37
40
41
43
45
47
49
53
55
55
56
58
Version 1.2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the V16 Plus and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BLUGUARD V16 Plus

  • Page 1: Table Of Contents

    V16 Plus USER MANUAL TABLE OF CONTENTS 1. INTRODUCTION………………………………………………………………………………... 2. TESTING…........................3. LIMITATIONS………………………………………………………………………………… … 4. WARNINGS……………………………………………………………………………………… 5. GLOSSARY……………………………………………………………………………………… 6. UNDERSTAND YOUR KEYPAD INDICATORS…………………………………………….. 7. SUMMARY OF OPERATION………………………………………………………………….. 8. TELEPHONY CONTROL DIAGRAM………………………………………………………….. 8 9. USER PROGRAMMING SUMMARY …………….…………………………………………... 10. ARMING THE SYSTEM……………………………………………………………….………..
  • Page 2: Introduction

    LIMITATIONS Even though BLUGUARD is an advanced security system, it does not 100% guarantee the protection against burglary, fire or other loses. Any alarm system whether commercial or residential is subjected to compromise or failure-to-warn for a variety of reasons.
  • Page 3: Glossary

    V16 Plus USER MANUAL GLOSSARY Alarm Memory This is the history of the most recent violations that occurred the last time when an alarm was triggered. To set the system into the ARMED mode. In this mode, a zone violation will activate an alarm condition.
  • Page 4: Understand Your Keypad Indicators

    V16 Plus USER MANUAL UNDERSTAND YOUR KEYPAD INDICATORS (LED) POWER INDICATOR PARTITION 1 ARM PARTITION 2 ARM MEMORY ZONE INDICATORS (GREEN) INDICATOR (Red) INDICATOR (Red) INDICATOR (Red) (Orange) Indicate the status of The indicator is The indicator is The indicator is...
  • Page 5 V16 Plus USER MANUAL UNDERSTAND YOUR KEYPAD INDICATORS (LCD) PARTITION 1 ARMED PARTITION 2 ARMED SERVICE INDICATOR MEMORY INDICATOR MUTE KEYPAD ICON ICON SOUND The icon is displayed The icon will be blinking The armed icon is The armed icon is...
  • Page 6: Summary Of Operation

    V16 Plus USER MANUAL SUMMARY OF OPERATION Intelligent Disarm [4-digit User Code] + [#] Intelligent Arming [4-digit User Code] + [#] Away Arm Hold down [1] for 2 seconds Day Arm Hold down [2] for 2 seconds Night Arm Hold down [3] for 2 seconds...
  • Page 7 V16 Plus USER MANUAL SUMMARY OF OPERATION PARTITION SYSTEM ENABLED Intelligent Disarm [4-digit User Code] + [#] + [Partition 1] or [Partition 2] Intelligent Arming [4-digit User Code] + [#] + [Partition 1] or [Partition 2] Away Arm Hold down [1] for 2 seconds + [Partition 1] or [Partition 2]...
  • Page 8: Telephony Control Diagram

    V16 Plus USER MANUAL TELEPHONY CONTROL DIAGRAM Call In to System: Dial Wait for [Master System System Voice Report on: Phone Code] + welcome Answer note and Number voice - Alarm triggered zone menu - System Arm / Disarm - Zone Open / Close / Bypassed...
  • Page 9: User Programming Summary

    V16 Plus USER MANUAL USER PROGRAMMING SUMMARY DIAGRAM (LED) The indicator is illuminated when the keypad is locked ER PROGRAMMING SUMMARY TABLE PROGRAM CODES MASTER CODE ENTER USER PROGRAMMING Press [01] + [New Code] + [Re-enter New Code] + [#]...
  • Page 10 V16 Plus USER MANUAL USER PROGRAMMING SUMMARY TABLE (LED)  Enter User Programming Mode ] + [MODE] + [4-digit Master Code] + [#] Exit User Programming Mode [MODE] + [#] Program New or Change Existing [01] + [New Master Code] + [Re-enter New Master Code] +...
  • Page 11 V16 Plus USER MANUAL USER PROGRAMMING SUMMARY TABLE (LED) 3. Master code, User Code 2,User Code 3 and User Code 4 are telephone remote access codes. These codes can ARM/DISARM the security system via local keypad or via telephone remote access.
  • Page 12 V16 Plus USER MANUAL USER PROGRAMMING SUMMARY DIAGRAM (LCD) The indicator is illuminated when the keypad is locked ER PROGRAMMING SUMMARY TABLE Zone 1 – 16 vocabulary setting Menu Zone Info HA Point 1 – 16 vocabulary setting HA Point Info...
  • Page 13 V16 Plus USER MANUAL USER PROGRAMMING SUMMARY TABLE (LCD)  Enter User Programming Mode : [ ] + [MODE] + [4-digit Master Code] + [#] / Enter from LCD Menu  Exit User Programming Mode : [ ] / Exit from LCD Menu...
  • Page 14 V16 Plus USER MANUAL USER PROGRAMMING SUMMARY TABLE (LCD) Program Security Timers Timers Arm P1 Timer Key in time [0000 to 2359] + [#] [F# to erase the previous setting] Disarm P1 Timer Key in time [0000 to 2359] + [#]...
  • Page 15 V16 Plus USER MANUAL USER PROGRAMMING SUMMARY TABLE (LCD) Program Security and Home Automation Timers Schedule Schedule Arm P1 Timer Press 1 for Monday 1 2 3 4 5 6 7 1 2 3 4 5 6 7 Disarm P1 Timer...
  • Page 16: Arming The System

    V16 Plus USER MANUAL ARMING THE SYSTEM There are various options for arming the system Partition Arming Away Arming Day Arming Night Arming Force Arming Holiday Arming Remote Control Arming Timer Auto Arming Telephone Remote Arming For information on how to ARM Partition system, please refer to PARTITIONING THE SYSTEM at page 28.
  • Page 17 V16 Plus USER MANUAL DAY ARMING (Press and hold down for 2 seconds) 1. This arming mode is ideal for DAY time arming with user still remains in the protected premises. 2. In this mode, the system will be armed instantly with certain preprogrammed, DAY STAY zones bypassed automatically.
  • Page 18 V16 Plus USER MANUAL FORCE ARMING (Press and hold down for 2 seconds) 1. In this mode, the system will be armed with EXIT delay time which allows certain violated zones to be bypassed temporary. When the violated zones resume, the zone will be protected again.
  • Page 19 V16 Plus USER MANUAL 10. After disarming, Home Automation random ON/OFF function will be deactivated and the system will resume to normal Home Automation ON/OFF timers setting. REMOTE CONTROL ARMING 1. This arming mode is ideal for remote control unit or key-switch arming.
  • Page 20: Disarming The System

    V16 Plus USER MANUAL DISARMING THE SYSTEM There are various options for disarming the system: a. Partition Disarming b. Keypad Disarming c. Remote Control Disarming d. Timer Auto Disarming e. Telephone Remote Disarm For information on how to DISARM Partition system, please refer to PARTITION DISARMING at page 35.
  • Page 21 V16 Plus USER MANUAL 8. If no valid user code has been entered by the end of the ENTRY delay period, an ALARM condition will be registered and stored into the system MEMORY. 9. If programmed to do so, the keypad will be locked and non-responsive for a preprogrammed period for certain number of incorrect user codes, which are entered consecutively more than the keypad lock counter.
  • Page 22: Turn On/Off Automation Point

    V16 Plus USER MANUAL TURN ON/OFF HOME AUTOMATION POINT + [HA POINT NUMBERS] + [#] (Press and hold down for 2 seconds) (1 to 16) 1. Enter and hold down [5] key for 2 seconds. The screen will show “HA Info” and 2.
  • Page 23: Un-Bypass Zone

    V16 Plus USER MANUAL 4. To enter zone number more than 9, press button [F] to represent the ten’s digit. 5. E.g. To enter zone number 12, press [F] + [2], zone number 16 press [F] + [6]. 6. Repeat step 3 to bypass other zones.
  • Page 24: View System Trouble

    V16 Plus USER MANUAL 9. Keypad audible indicator will sound 2 beeps to confirm the command and the system will be back to normal mode. 10. The relevant ZONE indicator will extinguish to indicate that the zone is now active.
  • Page 25: View Alarm Memory

    V16 Plus USER MANUAL VIEW ALARM MEMORY (Press and hold down for 2 seconds) 1. The system alarm memory will store the most recent alarm condition. An alarm condition will cause the following events. 2. The MEMORY indicator slow flash.
  • Page 26: Emergency Situation

    V16 Plus USER MANUAL confirm the command. e.g. To program zone 3 and zone 4 as CHIME zones: Press and hold down [9] for 2 seconds + [3] + [4] + [#] Keypad audible indicator will sound 2 beeps to confirm the command. Zone 3 and 4 are now CHIME zones.
  • Page 27 V16 Plus USER MANUAL MEDICAL MODE 1. The MEDICAL ALARM condition will be activated when: 2. Hold down [M] key for 2 seconds Press [MODE] followed by [9] and [#] 3. The keypad audible indicator will sound to indicate that a MEDICAL ALARM has been initiated.
  • Page 28: Partitioning The System

    V16 Plus USER MANUAL PARTITIONING THE SYSTEM Depending on your needs, your installer can program your control panel to recognize and control 2 separate areas (Partition 1 and Partition 2) by activating the system’s partitioning feature. User codes can also be programmed to ARM/DISARM one partition or both partitions simultaneously.
  • Page 29 V16 Plus USER MANUAL shown at the top right temporarily replace the clock. 6. The keypad audible indicator will sound on and off for the duration of the EXIT delay. 7. Any bypassed zones will be shown by the flashing zone indicators.
  • Page 30 V16 Plus USER MANUAL An EXIT delay countdown timer will be shown at the top right temporarily replace the clock. 6. The P2 indicator will illuminate if Partition 2 is armed. icon will be displayed if Partition 2 is armed.
  • Page 31 V16 Plus USER MANUAL the clock. 6. The keypad audible indicator will sound on and off for the duration of the EXIT delay. Any bypassed zones will be shown by the flashing zone indicators. 7. Leave the premises only via the EXIT/ENTRY zone.
  • Page 32 V16 Plus USER MANUAL PARTITION DAY ARMING [1 or 2] + [#] (Press and hold down for 2 seconds) 1. This arming mode is ideal for DAY time arming with user still remains in the protected premises. 2. In this mode, system will be armed instantly with certain preprogrammed, DAY STAY zones bypassed automatically.
  • Page 33 V16 Plus USER MANUAL 7. Enter key [1] to arm Partition 1 or enter key [2] to arm Partition 2 followed by [#] key. 8. The P1 indicator will illuminate if Partition 1 icon will be displayed if Partition is armed.
  • Page 34 V16 Plus USER MANUAL An EXIT delay countdown timer will be shown at the top right temporarily replace the clock. 7. Keypad audible indicator will sound on and off for the duration of the EXIT delay. Any bypassed zones will be shown by the flashing zone indicators.
  • Page 35: Partition Disarming

    V16 Plus USER MANUAL 11. User will be given an ENTRY delay time to disarm the system when enter the protected premises via ENTRY/EXIT zone. 12. After disarming, Home Automation random ON/OFF function will be deactivated and the system will resume to normal Home Automation ON/OFF timers setting.
  • Page 36: User Progarmming Mode

    In additional to Master Code, V16 Plus can be programmed to accept 13 user codes that allow you to arm/disarm the system. The default Master Code is “1234”.
  • Page 37: Exit User Programming Mode

    V16 Plus USER MANUAL  8. To exit user programming mode, press To exit user programming mode press [ [MODE] followed by [#] key. or exit from MENU. EXIT USER PROGRAMMING MODE  1. Press [MODE] followed by [#] key to exit.
  • Page 38 V16 Plus USER MANUAL Use the [▲] key and [▼] key to scroll up and down to select other user code and repeat step 3. Press [] to exit user programming mode. 8. If any of the user codes are not used, please ensure that they are all erased.
  • Page 39 V16 Plus USER MANUAL Press [] to exit user programming mode. 8. If any of the user codes are not used, please ensure that they are all erased. PROGRAM NEW AND CHANGING EXISTING DURESS CODE 1. Ensure that the system is in USER PROGRAMMING mode.
  • Page 40: Program System Timer

    V16 Plus USER MANUAL ERASE USER, DOOR ACCESS or DURESS CODE 1. Ensure that the system is in USER PROGRAMMING mode. 2. Enter [COMMAND ADDRESS] that you Press [#] to enter Passwords. wish to erase followed by [#] key. 3. Enter the 4-digit [0000] and re-enter the 4- Press [▼] to scroll down to select which...
  • Page 41: Program Partition 1 Auto Arm Timer

    V16 Plus USER MANUAL 3. Enter the [CURRENT TIME] in 24-hour Press [#] to enter Clock for system timer format, e.g. 8:00pm is 20:00. setting. 4. Enter [#] key to confirm the time. Enter the [CURRENT TIME] in 24-hour format e.g. 8:00pm is 20:00.
  • Page 42 V16 Plus USER MANUAL Enter the [AUTO ARM TIMER] in 24-hour 5. To exit user programming mode, press [MODE] followed by [#] key. format, e.g. 8:00pm is 20:00. Enter [#] key to confirm the time. Press [] to exit user programming mode.
  • Page 43: Program Partition 1 Auto Disarm Timer

    V16 Plus USER MANUAL PROGRAM PARTITION 1 AUTO DISARM TIMER 1. Ensure that the system is in USER PROGRAMMING mode. 2. Enter [19] for auto disarm timer setting. Press [▼] to scroll down to Timers. 3. Enter the [AUTO DISARM TIMER] in 24- Press [#] to enter Timers.
  • Page 44 V16 Plus USER MANUAL TO ERASE PARTITION 1 AUTO DISARM TIMER 1. Ensure that the system is in USER PROGRAMMING mode. 2. Enter [19] for auto disarm timer setting. Press [▼] to scroll down to Timers. 3. Enter the [#] key to erase previous AUTO Press [#] to enter Timers.
  • Page 45: Program Partition 2 Auto Arm Timer

    V16 Plus USER MANUAL PROGRAM PARTITION 2 AUTO ARM TIMER 1. Ensure that the system is in USER PROGRAMMING mode. 2. Enter [20] for auto arm timer setting. Press [▼] to scroll down to Timers. 3. Enter the [AUTO ARM TIMER] in 24-hour Press [#] to enter Timers.
  • Page 46 V16 Plus USER MANUAL TO ERASE PARTITION 2 AUTO ARM TIMER 1. Ensure that the system is in USER PROGRAMMING mode. 2. Enter [20] for auto arm timer setting. Press [▼] to scroll down to Timers. 3. Enter the [#] key to erase previous AUTO Press [#] to enter Timers.
  • Page 47: Program Partition 2 Auto Disarm Timer

    V16 Plus USER MANUAL PROGRAM PARTITION 2 AUTO DISARM TIMER 1. Ensure that the system is in USER PROGRAMMING mode. 2. Enter [21] for auto disarm timer setting. Press [▼] to scroll down to Timers. 3. Enter the [AUTO DISARM TIMER] in 24- Press [#] to enter Timers.
  • Page 48 V16 Plus USER MANUAL TO ERASE PARTITION 2 AUTO DISARM TIMER 1. Ensure that the system is in USER PROGRAMMING mode. 2. Enter [21] for auto disarm timer setting. Press [▼] to scroll down to Timers. 3. Enter the [#] key to erase previous AUTO Press [#] to enter Timers.
  • Page 49: Program Auto On Timer 1/2/3/4 For Home Automation

    V16 Plus USER MANUAL PROGRAM AUTO ON TIMER 1/2/3/4 FOR HOME AUTOMATION 1. Ensure that the system is in USER PROGRAMMING mode. 2. Enter [22] for auto on timer 1 setting.* Press [▼] to scroll down to Timers. 3. Enter the [AUTO ON TIMER 1] in 24-hour Press [#] to enter Timers.
  • Page 50 V16 Plus USER MANUAL TO ERASE AUTO ON TIMER 1/2/3/4 FOR HOME AUTOMATION 1. Ensure that the system is in USER PROGRAMMING mode. 2. Enter [22] for auto on timer 1 setting.* Press [▼] to scroll down to Timers. 3. Enter the [#] key to erase previous AUTO Press [#] to enter Timers.
  • Page 51: Program Auto Off Timer 1/2/3/4 For Home Automation

    V16 Plus USER MANUAL PROGRAM AUTO OFF TIMER 1/2/3/4 FOR HOME AUTOMATION 1. Ensure that the system is in USER PROGRAMMING mode. 2. Enter [23] for auto off timer 1 setting.* Press [▼] to scroll down to Timers. 3. Enter the [AUTO OFF TIMER 1] in 24-hour Press [#] to enter Timers.
  • Page 52 V16 Plus USER MANUAL TO ERASE AUTO OFF TIMER 1/2/3/4 FOR HOME AUTOMATION 1. Ensure that the system is in USER PROGRAMMING mode. 2. Enter [23] for auto off timer 1 setting.* Press [▼] to scroll down to Timers. 3. Enter the [#] key to erase previous AUTO Press [#] to enter Timers.
  • Page 53: Program Personal Telephone Number 1/2/3/4

    V16 Plus USER MANUAL PROGRAM PERSONAL TELEPHONE NUMBER 1/2/3/4 1. Ensure that the system is in USER PROGRAMMING mode. 2. Enter [30] for personal telephone number 1 Press [▼] to scroll down to TelNos. setting.* 3. Enter [PERSONAL TELEPHONE Press [#] to enter TelNos.
  • Page 54 V16 Plus USER MANUAL 12. If the system fails to contact the preprogrammed personal telephone number 1, system will contact PERSONAL TELEPHONE NUMBER 2 to 4 as a backup. If the system fails to report to all telephone numbers, a new trouble condition will be registered (please refer to View System Trouble).
  • Page 55: Program System Date

    V16 Plus USER MANUAL * Enter [31] for personal telephone number 2 setting OR Enter [32] for personal telephone number 3 setting OR Enter [33] for personal telephone number 4 setting. ** Press [▼] to scroll down to User TelNo2 and press [#] to enter for personal telephone number 2 setting OR Press [▼] to scroll down to User TelNo3 and press [#] to enter for personal telephone number 3 setting OR...
  • Page 56: Testing The System

    V16 Plus USER MANUAL 4. Press [#] to access Arm P1 Timer Schedule for auto arm partition 1 timer schedule. 5. The default setting is number 1 to 7 ON (1 for Monday, 2 for Tuesday, 3 for Wednesday, 4 for Thursday, 5 for Friday, 6 for Saturday and 7 for Sunday).
  • Page 57 V16 Plus USER MANUAL CMS TEST (Manual Test) 1. CMS Test allows on-site testing of CMS Reporting. 2. Press [MODE] + [2] + [#]. Press [MODE] + [2] + [#] or enter from MENU. (Menu  System Test  CMS Test) 3.
  • Page 58: System Information

    V16 Plus USER MANUAL BATTERY TEST 1. Battery Test allows on-site testing of battery functionality. 2. Press [MODE] + [5] + [#]. Press [MODE] + [5] + [#] or enter from MENU. (Menu  System Test  Battery Test) 3. Wait for 5 seconds, if back-up battery fails then a new trouble condition will be registered.
  • Page 59 V16 Plus USER MANUAL SYSTEM SETTING INFORMATION Partition 1 Entry Time Partition 1 : _____________________________ seconds Exit Time Partition 1 : _____________________________ seconds Siren Cut-Off Time for Partition 1 : _____________________________ minutes Partition 2 Entry Time Partition 2 : _____________________________ seconds...