Mux Mode; The Mux Mode - Western Telematic MDS-16 User Manual

Multipurpose data switch
Table of Contents

Advertisement

MDS Series User’s Guide
To retrieve data from buffer memory, issue the /R (Read Buffer)
command at any port that is configured for the Any-to-Any
Mode. The /R command uses the following format:
Where:
nn
Is the number or name of the port buffer to be read.
/C
(Optional) Causes data to be deleted from the port buffer
after it has been read. Note that the /R/C option is only
available to ports that have All (Administrator)
Command Availability.

6.3. Mux Mode

The Mux Mode allows data from several sources to be
multiplexed to a common output port, regardless of
dissimilarities between baud rate, parity, and etc..
Ports that are configured for the Mux Mode will send data to a
user specified Mux Output Port. Data records will be terminated
by the user defined End-of-Record character, and/or by user
defined block size. The Mux Mode is not available to MDS
Port 1. Note that data collected by a Mux Input Port will not be
released until the End-of-Record character is sent, or the block
size requirement is met.
Figure 6.3: The Mux Mode
6-10
/R[/C] nn [Enter]

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mds-8

Table of Contents