Switch Mode Owner's Please read this manual BEFORE Manual DC Power installing your Supplies Power Supply. SEC-1235 SEC-1235M SAMLEX AMERICA, INC.
SECTION 1 | Important Safety Instructions CAUTION: RISK OF ELECTRIC SHOCK! DO NOT OPEN! TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. THERE ARE NO USER SERVICEABLE PARTS INSIDE—REFER TO QUALIFIED SERVICE PERSONNEL.
SECTION 2 | Layout & Dimensions Figure 2.1 Layout & Dimensions - SEC-1235 1. Lighted Power ON/OFF Rocker Switch (Lights Red when ON) 2. AC Power Cord Inlet: Type “IEC 320-C14” for detachable power cord with “IEC 320-C13” connector on one end and NEMA5-15P plug on the other end.
Page 5
SECTION 2 | Layout & Dimensions Figure 2.2 Layout & Dimensions - SEC-1235M 1. Lighted Power ON/OFF Rocker Switch (Lights Red when ON) 2. AC Power Cord Inlet: Type “IEC 320-C14” for detachable power cord with “IEC 320-C13” connector on one end and NEMA5-15P plug on the other end. 3.
| Product Overview Description & Features SEC-1235 & SEC-1235M are Switched Mode Power Supplies (SMPS) which convert 120V, 50/60 Hz (or 230V, 50/60 Hz*) AC power to regulated 13.8V DC power based on Pulse Width Modulation (PWM) control. Note*: The units are factory preset to operate from an input voltage of 120 VAC, 50/60 Hz.
Page 7
SECTION 3 | Product Overview NOTE: The DC output connectors (RED + and Black -) have a tubular hole of diameter 0.2” (5mm) with a set screw. If bare wire with stranded conductors is used to connect the load to the above output connectors of the power supply, the strands will spread out as the set screw is tightened and hence, the set screw will not pinch all the strands.
Page 8
13.8V when fully charged and the current drawn by the battery reduces a few hundred mA. If a deeply discharged battery is directly charged by SEC-1235 / SEC-1235M, the battery will initially draw a very large current and thus, will force the power supply into current limit mode for prolonged period of time.
SECTION 4 | Troubleshooting Guide Symptom Possible Cause Remedy ON / OFF Switch is ON No AC power from the Check AC power is available at the AC • Switch is NOT lighted AC outlet outlet. Breaker feeding the AC outlet may •...
Section 5 | Limiting Electromagnetic Interference CAUTION! Conducted and radiated noises in this unit are limited as per the applicable National / Inter- national Standards. In North America, the applicable standard is FCC Part 15(B) for Class “B” Digital Devices for Residential Installations. The corresponding European standard is EN55022, Class “B”...
Page 11
Section 5 | Limiting Electromagnetic Interference Then, if necessary, relocate either the antenna or the power supply farther apart. The receiver may “hear” the power supply. A slowly moving, slightly buzzing carrier heard in the receiver may be caused by the antenna being too close. As with the transmitter related noise pick up, a loose coaxial connector or a broken or a missing ground may aggravate this problem.
Page 12
Section 5 | Limiting Electromagnetic Interference proportional to the person’s skin resistance will flow through the person’s body to Earth Ground. The leakage current through the body is higher when the skin contact resist- ance is lower i.e. if the skin is wet or wounded. This leakage current does not return to the power source but is dissipated in Earth Ground.
SECTION 6 | Specifications SEC-1235 SEC-1235M AC INPUT Nominal AC Input Volt- 120 VAC (100-130VAC), 50/60 Hz : Factory Preset 230VAC (200 – 260VAC), 50/60Hz: By internal jumper setting Input Current 7.5 A @ 120 VAC; 3.5A @ 230VAC Input Current at No Load 120 mA ±...
Page 14
SECTION 6 | Specifications SEC-1235 SEC-1235M FUSE • 5 mm x 20 mm Glass Fuse Internal AC Side Fuse, • 250V, 8A, Time Delay Type 120VAC Input (Preset) • LittelFuse - “218008” • 5 mm x 20 mm Glass Fuse Internal AC Side Fuse, • 250V, 4A, Time Delay Type...
| Warranty 3 YEAR LIMITED WARRANTY SEC-1235/SEC-1235M manufactured by Samlex America, Inc. (the “Warrantor“) is warrant- ed to be free from defects in workmanship and materials under normal use and service. The warranty period is 3 years for the United States and Canada, and is in effect from the date of purchase by the user (the “Purchaser“).
Information Toll Free Numbers Ph: 800 561 5885 Fax: 888 814 5210 Local Numbers Ph: 604 525 3836 Fax: 604 525 5221 Website www.samlexamerica.com USA Shipping Warehouse Kent WA Canadian Shipping Warehouse Delta BC Email purchase orders to orders@samlexamerica.com 11001-SEC-1235-1235M-1114...