Programming The Initial Setup Menu - Wallace International Kinetic DC 15W Installation And Maintenance Manual

Table of Contents

Advertisement

Installing the Drive on Gate Post

Programming the Initial Setup Menu:

Several sequential displays present information which must be configured before Kinetic operator will
function. Once the configuration is complete, the information is retained even when a power loss occurs.
Table 1-1. Menu Mode Navigational Buttons
To Edit the Menu
Press SELECT
Two top characters blink.
Note: Programming the Setup Menu is usually a one-time occurrence unless factory defaults are reinstated
through the Installer Menu. The RESET and MENU buttons do not function during the initial
configuration of the Setup Menu.
SELECTIONS
0
- No Usage Class set.
1
- Single family residential up to four units.
2
- Multi-family, hotel etc.
3
- Industrial use, not for general public
4
- Guarded and monitored facility, not for general public
SELECTIONS
0
- No handing set. Gate will not move until handing is set.
Looking at gate from secure side:
L - If the gate slides open to the left.
R - If the gate slides open to the right.
SELECTIONS
0
- Gate weight not set.
Kinetic DC 15W
1
- Gate weight
2
- Gate weight 401 to 800lbs (181 to 363kg)
3
- Gate weight 801 to 1100lbs (363 to 499kg)
4
- Gate weight 1101 to 1500lbs (499 to 680kg)
Kinetic DC 10FW
1
- Gate weight
2
- Gate weight 251 to 500lbs (114 to 227kg)
3
- Gate weight 501 to 750lbs (227 to 340kg)
4
- Gate weight 751 to 1000lbs (340 to 454kg)
1-6
 
To navigate through
the SELECTIONS
Press NEXT.
Continue pressing NEXT
to view all selections.
0 to 400lbs
(0 to 181kg)
0 to 250lbs
(0 to 114kg)
To choose what is
on the display
Press SELECT.
Blinking characters become
static.
To navigate
between menus
Press NEXT or PREV.
Advance – Press NEXT
Previous – Press PREV.
Figure 1-11
Rev: A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kinetic dc 10fw