Page 1
Ademco Vista-10P Low Battery Warning When the keypad displays BAT with no zone number, this indicates that the system back up battery needs to recharge. If AC power is out, the security system may shut down once the battery is below the operating level. When AC power is restored, the panel recharges the battery.
Page 2
Locating Control Panel Box The battery control panel box is typically located inside a closet, garage or attic. Please note: the control box is different from the panel keypad that is used to arm and disarm the security system. Install New Battery 1.
Page 3
5. Installing New Battery Place the new battery inside the control panel box. 1. If the replacement battery has plastic terminal protectors, remove them before connecting the wires to the battery. 2. Connect the red wire to the red or (+) terminal of the new battery by pushing the connector firmly onto the terminal.
Page 4
1. Enter the 2-digit hour setting. 2. Enter the 2-digit minute setting. 3. Press [1] for PM or [0] for AM. 4. Enter the last two digits of the current year. 5. Enter the 2-digit month setting. 6. Enter the 2-digit day setting. 3.
Page 5
5. Safety Warnings & Hazards Do not throw the battery in fire to heat the battery. The battery may burst or generate a toxic gas if placed in contact with fire. Warning: the battery contains diluted sulfuric acid, a very toxic substance. If the battery leaks and the liquid spills on skin or clothing, immediately wash it off with plenty of clean water.