Sony HCD-DZ520K Service Manual page 4

Table of Contents

Advertisement

QQ
3 7 63 1515 0
(3) Select "5. MIRR time Adjust".
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment
4. Mecha test mode
5. MIRR time Adjust
0. Return to Top Menu
(4) Select "5. Default set MIRR time".
MIRR time Adjust Menu
1. CD MIRR time Check:
2. DVD MIRR time Check:
3. Threshold:
4. Save to EEPROM:
5. Default set MIRR time:
[Open] Tray open [Close] Tray close
[0] Return to previous menu
(5) Select "3. Threshold".
(6) Confirm the number. If it is 7D, go to next step. If it is any
other value, return to step 4.
MIRR time Adjust Menu
1. CD MIRR time Check:
TE
L 13942296513
2. DVD MIRR time Check:
3. Threshold: 7D
4. Save to EEPROM:
5. Default set MIRR time:
[Open] Tray open [Close] Tray close
[0] Return to previous menu
(7) Push the A button to eject tray.
(8) Insert Test Disc HLX-504 into tray.
(9) Push the A button to close tray.
(10) Push "2. DVD MIRR time Check".
(11) Wait for HEX number to display.
(12) Confirm the number, if XX is 28 – 70, proceed with next
step. If no, return to 8.
MIRR time Adjust Menu
1. CD MIRR time Check:
2. DVD MIRR time Check: XX XX
3. Thereshold:
4. Save to EEPROM:
5. Default set MIRR time:
[Open] tray open [close] Tray close
[0] Return to previous menu
www
(13) Push "4. Save to EEPROM".
.
http://www.xiaoyu163.com
x
ao
u163
y
i
http://www.xiaoyu163.com
2 9
8
(14) Confirm the same values are displayed. If it is not same,
return to step 7.
MIRR time Adjust Menu
1. CD MIRR time Check:
2. DVD MIRR time Check: XX XX
3. Threshold:
4. Save to EEPROM:
5. Default set MIRR time:
[Open] Tray open [close] Tray close
[0] Return to previous menu
(15) Push the A button to eject tray.
(16) Take out HLX-504 and insert Test Disc YEDS-18 into
tray.
(17) Push the A button to close tray.
(18) Push "1. CD MIRR time check".
(19) Wait for HEX number to display.
(20) Confirm the number, if YY is 5A – E8, proceed with next
step. If no, return to 15.
MIRR time Adjust Menu
1. CD MIRR time Check: YY YY
Q Q
2. DVD MIRR time Check: XX XX
3
6 7
1 3
1 5
3. Threshold:
4. Save to EEPROM:
5. Default set MIRR time:
[Open] Tray open [close] Tray close
[0] Return to previous menu
(21) Push "4. Save to EEPROM".
(22) Confirm the same values are displayed. If it is not the
same, return to step 15.
MIRR time Adjust Menu
1. CD MIRR time check: YY YY
2. DVD MIRR time check: XX XX
3. Threshold:
4. Save to EEPROM:
5. Default set MIRR time:
[Open] Tray open [close] Tray close
[0] Return to previous menu
(23) Push the A button to eject tray.
(24) Remove Test Disc YEDS-18 from tray.
(25) Push the A button to close tray.
(26) Press the 0 "R" button to the Drive Manual Operation menu.
co
(27) Press the 0 "R" button to return to the Remocon Diagnosis
Menu.
.
(28) Press the ?/1 button to switch OFF set.
HCD-DZ520K/DZ620K
9 4
2 8
0 5
8
2 9
9 4
2 8
m
9 9
9 9
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hcd-dz260l

Table of Contents