Cause: The voltage in the power supply section is
abnormal.
Supplementary information: The abnormal voltage is
displayed in % based on 5V as 100%.
Turning on the power without correcting the abnormality
will cause the protection function to work 1 second later
and the power supply will be shut off.
Cause: DC output of the power amplifier is abnormal.
Supplementary information: The abnormal voltage is
displayed in % based on 5V as 100%.
Turning on the power without correcting the abnormality
will cause the protection function to work 3 seconds later
and the power supply will be shut off.
Cause: The temperature of the heat sink is excessive.
Supplementary information: The abnormal voltage is
displayed in % based on 5V as 500%.
Turning on the power without correcting the abnormality
will cause the protection function to work 1 second later
and the power supply will be shut off.
* Additional causes of protection can be due to loose
connections, associated components, CPU, etc.
* For the protection voltage value, refer to DIAG menu
No.12 described later.
When there is a history of protection
function due to abnormal voltage in
the power supply section
Voltage display in %
When there is a history of protection
function due to abnormal DC output
When there is a history of protection
function due to excessive heat sink
temperature
Voltage display in %
Version (1 alphabet)
Version (1 alphabet)
Version (1 alphabet)
RX-V1500/DSP-AX1500
23