Page 1
SAM400 & 650 PERKINS DIESEL ENGINE DRIVEN MULTI-PROCESS DC ARC WELDING POWER SOURCES For use with SAM400 machines having Code Numbers: 10140 & 10141 For use with SAM650 machines having Code Number: 10333 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind.
Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of “Arc Welding Safety” booklet E205 is available from the Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199. BE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE AND REPAIR PROCEDURES ARE PERFORMED ONLY BY QUALIFIED INDIVIDUALS.
(MSDS) and follow your employer’s safety practices. MSDS forms are available from your welding distributor or from the manufacturer. 5.e. Also see item 1.b. SAM400 & 650 which require special Mar ‘95...
Page 4
8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations. 8.c. Ground the equipment in accordance with the U.S. National Electrical Code and the manufacturer’s recommendations. Mar ‘95 SAM400 & 650 compressed cylinders...
Page 5
électricien qualifié. 3. Avant de faires des travaux à l’interieur de poste, la debranch- er à l’interrupteur à la boite de fusibles. 4. Garder tous les couvercles et dispositifs de sûreté à leur place. SAM400 & 650 Mar. ‘93...
Page 6
This statement appears where the information must be followed to avoid minor personal injury or damage to this equipment. for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product •••...
5. Conformance with federal, state and local laws. Consult applicable federal, state and local laws regarding specific requirements for use on public highways. SAM400 & 650 WARNING...
DO NOT OVERTIGHTEN. Muffler: On SAM650 units: Screw the muffler into the exhaust flange and tighten. On SAM400 units with the optional noise control muffler: Attach the muffler with the supplied hardware. The engine and welder controls were properly set at the factory and should require no adjusting when received.
PIPE BEFORE REVIEWING LINCOLN BULLETIN E695.1 (dated May 1987 or later). This bulletin may be obtained from your local Lincoln distributor or by writ- ing directly to Lincoln Electric at the address on the back of this manual. ADDITIONAL SAFETY PRECAUTIONS...
#75 and #76 on the SAM terminal strip locat- ed behind the lower cover panel directly below the con- trol panel on the SAM400 or behind the right front hinged door on the SAM650. Connect the green lead of the “Portable Field Control”...
Page 14
“Amps” or “Wire Feed Speed” control on the wire feeder. Low Range Feature (SAM400 K1279-1 only) -- Extends the output voltage range of the SAM400 welder down to 12 volts for constant voltage welding. The maximum output current is not to exceed the rat- ing of the machine.
Page 15
“Variable Voltage Control” can usually be left between 7 and “High” -- no future adjustments are needed. b. Set SAM400 “Current Control” so the calibration on the higher scale is a little above the current desired. Set the SAM650 “Tap” lead to the stud with the lowest current range that still provides the desired current.
Duty cycle is based on a ten minute period and opera- tion in an ambient temperature of 104°F(40°C). The SAM400 is NEMA rated at 60% duty cycle. The SAM650 is NEMA rated at 80% duty cycle. Duty cycle is based on a ten minute period. Therefore, a 60% duty...
K704(SAM400 only) Standard Accessory Kit - Includes electrode and work cables, headshield, work clamp and electrode holder. K865(SAM400 only) Engine Hour Meter Kit - (Standard on K1279-1). Keeps track of how long engine has been operated. Useful for following recom- mended maintenance schedules on machine.
Use low pressure air to avoid driving dirt into the insulation. 2. The SAM400 current control reactor brushes are self-lubricating and should not be greased. Keep the contacts clean. This control should be moved from maximum to minimum daily to prevent the controls from sticking.
Page 23
1/8”. Less than 1/16” compression indicates worn contacts that should be replaced. 3. Make sure the moving contact or other moving parts are not binding. 4. Check interlock contacts and springs. Be sure mounting screws are tight. SAM400 & 650 APR97...
HOW TO USE TROUBLESHOOTING GUIDE Service and Repair should only be performed by Lincoln Electric Factory Trained Personnel. Unauthorized repairs performed on this equipment may result in danger to the technician and machine operator and will invalidate your factory warranty. For your safety and to avoid Electrical Shock, please observe all safety notes and precautions detailed throughout this manual.
Page 25
Phase Bridge. 2. Test for failure of Control Board 3. Test for Defective Toggle Switch, Rheostat or Open Circuit CAUTION SAM400 & 650 RECOMMENDED COURSE OF ACTION 1. Check diodes D7, D8, D9, D10, D11. (See Diode Test Procedure) 2. a) Turn machine off.
Page 26
POSSIBLE CAUSE FUNCTION PROBLEMS Test Alternator Rotor Voltage (80- 90 Volts DC) Lead #222 to #1 CAUTION SAM400 & 650 RECOMMENDED COURSE OF ACTION 1. If rotor voltage present go to Step 9. If no rotor voltage go to Step 2.
Page 27
POSSIBLE CAUSE FUNCTION PROBLEMS SCR Bridge Test (See Procedure) Continuity test. (Note B Pg. E-2). CAUTION SAM400 & 650 RECOMMENDED COURSE OF ACTION 10. Voltage higher than 22 volts DC. a) If between 22 and 100 volts, replace both Control Boards. (Note A Pg. E-2).
Page 28
Test rotor voltage (80-90 volts DC) Test alternator outputs (22-24 volts DC) CAUTION SAM400 & 650 RECOMMENDED COURSE OF ACTION 1.Make continuity test outlined in Step 3, on page E-2 except turn voltage con- trol from maximum (0 ohms) to mini- mum (10,000 ohms).
R28 (about 1200 ohms) in both directions. If D3 is shorted, you will read zero ohms or a very low resistance in both directions. 7. If the board fails any of the tests, replace it. SAM400 & 650 CAUTION ), use that range for this test. Otherwise...
2. Turn variable voltage control and portable field control to high. 3. Set Trimmer #3 so that OCV is 95±1 volts DC on SAM400 machines or 89±1 volts for SAM650 machines. 4. Turn variable voltage rheostat and portable field control to low.
#75 on SCR bridge. 11. Across each of the three-phase bridge diodes, jumper from the heat sink across the diode on all six diodes. NOTE: All jumpers must be as short as possible TROUBLESHOOTING SAM400 & 650...
PARTS covers are replaced after servicing. CAN INJURE THERMOSTART (SAE UNITS ONLY) AMMETER START IGNITION SWITCH FUEL INJECTION STARTING PUMP MOTOR SAM400 & 650 THERMOSTART IGNITER COLD TERMINAL TO CR7 (SAM UNITS ONLY) M16879 4-3-92A...
Page 37
® ® |_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_| Account No. USE THIS FORM TO ORDER: Order from: BOOK DIVISION, The Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199 BOOKS OR FREE INFORMATIVE CATALOGS Lincoln Welding School Titles: (ED-80) New Lessons in Arc Welding Seminar Information Procedure Handbook “Twelfth Edition”...
Page 38
Gardez à l’écart de tout matériel inflammable. Entfernen Sie brennbarres Material! Mantenha inflamáveis bem guarda- dos. SAM400 & 650 Wear eye, ear and body protection. Protéjase los ojos, los oídos y el cuerpo. Protégez vos yeux, vos oreilles et votre corps.
Page 39
Anlage nie ohne Schutzgehäuse oder Innenschutzverkleidung in Betrieb setzen! Mantenha-se afastado das partes moventes. Não opere com os paineis abertos ou guardas removidas. SAM400 & 650 WARNING Spanish AVISO DE PRECAUCION French ATTENTION German WARNUNG Portuguese ATENÇÃO...
INCLUDING: PARTS & LABOR S22127-3 LIMITED WARRANTY TO OBTAIN WARRANTY COVERAGE: You are required to notify Lincoln Electric, your Lincoln Distributor, Lincoln Service Center or Field Service Shop of any defect within the warranty period. Written notification is recommended. WARRANTY REPAIR:...