INstAllER: leave this manual with the appliance.
coNsUmER: Retain this manual for future reference.
In the commonwealth of massachusetts:
Installation must be performed by a licensed plumber or
gas fitter;
• See Table of Contents for location of additional Common-
wealth of massachusetts requirements.
WARNINg: If the information in this manual is
not followed exactly, a fire or explosion may
result causing property damage, personal injury
or loss of life.
FoR yoUR sAFEty: Do not store or use gasoline
or other flammables or liquids in the vicinity of
this or any other appliance.
FoR yoUR sAFEty: What to do if you smell gas:
• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow your gas suppliers
instructions.
• If your gas supplier cannot be reached, call
the fire department.
Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
Portland
US
otl Report No.116-F-38c-5
INstAllAtIoN AND

oPERAtIoN INstRUctIoNs

UNIVERSAL VENT-FREE FIREBOX
36" x 24" Universal Vent-Free Fireboxes
P/N 506009-07 REV. A 05/2013
MODEL
EWVF36
FoR UsE oNly WIth A lIstED gAs-FIRED
UNVENtED DEcoRAtIVE Room hEAtER Not to
EXcEED 40,000 btU/h.
Do Not bUIlD A WooD FIRE.
WARNINg: ImPRoPER INstAllAtIoN, ADjUst-
mENt, AltERAtIoN, sERVIcE oR mAINtENANcE
cAN cAUsE INjURy oR PRoPERty DAmAgE.
REFER to thIs mANUAl. FoR AssIstANcE oR
ADDItIoNAl INFoRmAtIoN coNsUlt A qUAlI-
FIED INstAllER, sERVIcE AgENcy oR thE gAs
sUPPlIER.
carefully review the instructions supplied with
the decorative type unvented room heater for the
minimum fireplace size requirement.
Do Not INstAll AN APPlIANcE IN thIs FIREboX
UNlEss thIs FIREboX mEEts thE mINImUm
DImENsIoNs REqUIRED FoR thE INstAllAtIoNs.
thIs Is A VENt-FREE gAs-FIRED hEAtER ENclo-
sURE. It UsEs AIR (oXygEN) FRom thE Room
IN WhIch It Is INstAllED. PRoVIsIoNs FoR
ADEqUAtE combUstIoN AND VENtIlAtIoN AIR
mUst bE PRoVIDED. REFER to combUstIoN
AND VENtIlAtIoN AIR sEctIoN, PAGE 4.
Due to high temperatures, the appliance should be located out
of traffic and away from furniture or draperies.
Do not place clothing or other materials on or near this appliance.
ImPoRtANt: READ AND UNDERstAND thEsE INstRUctIoNs
comPlEtEly bEFoRE INstAllINg yoUR VENt-FREE Room
hEAtERs.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EWVF36 and is the answer not in the manual?

Questions and answers

Summary of Contents for Everwarm EWVF36

  • Page 1: Operation Instructions

    UNIVERSAL VENT-FREE FIREBOX 36" x 24" Universal Vent-Free Fireboxes P/N 506009-07 REV. A 05/2013 MODEL EWVF36 FoR UsE oNly WIth A lIstED gAs-FIRED INstAllER: leave this manual with the appliance. UNVENtED DEcoRAtIVE Room hEAtER Not to coNsUmER: Retain this manual for future reference.
  • Page 2: Important Safety Information

    ImPoRtANt sAFEty WARNINg WARNINg INFoRmAtIoN carbon monoxide Poisoning: Early • The heater must be isolated from INstAllER: PlEAsE lEAVE thEsE INstRUc- signs of carbon monoxide poisoning the gas supply piping system by tIoNs WIth thE oWNER. closing its individual manual are similar to the flu with head- oWNER: PlEAsE REtAIN thEsE INstRUc- shut-off valve during any pres-...
  • Page 3: Table Of Contents

    / standards The Installation must conform to local codes or, In selecting this Everwarm Vent-Free Gas Firebox you have chosen the finest and most dependable fireplace to be found anywhere. A beautiful, prestigious, alternative to a wood in the absence of local codes, with the National burning fireplace.
  • Page 4: Combustion And Ventilation Air

    combUstIoN AND VENtIlAtIoN AIR 2. Divide the volume of space by 50 ft Your options are: determine the maximum BTu/Hr the space can support. Heaters installed in these appliances shall a. Rework equations adding the space of adjoin- not be installed in a confined space. Heaters ing room(s).
  • Page 5: Requirements For The Commonwealth Of Massachusetts

    (e)unvented propane or natural gas-fired space/room heaters shall NOTE: The following requirements reference various Massachusetts and national codes not contained in this document. be prohibited in bedrooms and bathrooms. (f)Space/room heaters shall be properly sized for the room or space Requirements for the commonwealth of massachusetts of installation, but shall not exceed a maximum of 40,000 BTu input per room or space.
  • Page 6: Location Of Firebox

    Top of Appliance installation. Failure to follow these requirements shown with hood Installed (required may create a fire hazard. on EWVF36) sidewall clearances: The sides of the firebox Fireplace opening must be at least 16" from any com- Opening bustible wall (Figure 2).
  • Page 7 To install the firebox with a wood mantel, shelf or other combustible projection above firebox opening. Model EWVF36 WITH Hood Installed Refer to Figure 4. Hood is required on all installations for this model.
  • Page 8: Assembly Steps

    AssEmbly stEPs consult all local codes. ImPoRtANt NOTES: Properly size and route the gas supply line hold heater regulator with a wrench • Illustrations shown in this manual reflect from the supply regulator to the area where the to prevent movement when connect- “typical”...
  • Page 9: Firebox Framing

    Firebox Framing 3. Note the floor construction, i.e. 2" x 6", 2" x NOTE: The nailing flange and the area directly 8" or 2" x 10", single or double joists, type behind the nailing flange is exempt from the clearances described on the firebox clearance and thickness of floor boards.
  • Page 10: Specifications

    (33) (140) (770) (753) Product Reference Information * A hood comes standard and is required for model EWVF36. The factory- supplied hood must be installed on the firebox for safe operation in all model ship. Weight (lbs) shipping Volume installations.
  • Page 11: Framing Specifications

    NOTE: A hood comes standard and is required for model EWVF36. The Reinstalling screens and Rods: factory-supplied hood must be installed on the firebox for safe opera- Insert rods into corresponding tion for model EWVF36 in all installations.
  • Page 12: Optional Equipment / Blower Kit Installation

    ImPoRtANt top View * junction box * Electrical outlet the Ground Lead must be connected to the green screw (located on the hood junction box). Failure to do this blower could result in an electrical short or Bend blower mounting shock injury.
  • Page 13 Page 14). step 1. Follow the instructions below for the model you are installing: screw model EWVF36: strain Relief bushing Using a screwdriver remove the screw from the blower access panel as shown in Figure 15. Slide the panel to the right until the flange...
  • Page 14 10. Follow the instructions below for the model you are installing: side of appliance. model EWVF36: step 7. Locate the J-Box cover (provided in J-Box Kit). Remove the round Reinstall the blower access panel that was removed on Step 1 (see knock-out (see Figure 16).
  • Page 15: Firebox Finishes

    FIREboX FINIshEs and wall surrounds to prevent air intrusion. Use noncombustible caulking material only to seal the black metal facing to the surround material on the finished wall. See Figures 3 and 23. There are a wide variety of “finished looks” for your built-in Vent-Free firebox from formal wall decor with elaborate mantels to rustic wood Raised hearth Extension paneling or warm brick facings.
  • Page 16 APPRoVED AccEssoRIEs AND comPoNENts The variable speed control rheostat is included with EWFBK200 models only Touch-Up Paint Kits model No. Description Junction Box / Receptical Kit FTPK-B touch-Up Paint (black) An locally sourced ON/OFF wall switch model No. Description (ref. Form # 750050m) can be used with the EWFBK 100 models Junction Box / Electrical Kit EWJBK...
  • Page 17: Replacement Parts List

    4. The description of the part. approved with this appliance may result in property 5. The quantity required. 6. The installation date of the firebox. damage or personal injury. EWVF36 Description Part No. qty. Gas Fireplace Assembly Firescreen...
  • Page 18 CuI reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. Printed in U.S.A. © 2013 CUI 1026 Old Stage Rd. P/N 506009-07 REV.

Table of Contents