A-1
TECHNICAL SPECIFICATIONS - SAE-400 SEVERE DUTY
Make/Model
Description
Perkins
4 cylinder
1004.42 Diesel
71 HP @
Engine
1725 RPM
Duty Cycle
(1)
60% (NEMA)
60% (Lincoln Plus)
Welding Range
80 - 575 Amps
HEIGHT
52.00 in.
1320.8 mm
(1)
Based on a 10 minute period.
INSTALLATION
INPUT - DIESEL ENGINE
Speed (RPM)
High Idle 1800
Low Idle 1100
Full Load 1725
RATED OUTPUT - WELDER
Welding Output
400 amps
400 amps
OUTPUT - WELDER AND GENERATOR
Open Circuit Voltage
97 Max. OCV
@ 1800 RPM
PHYSICAL DIMENSIONS
WIDTH
28.00 in.
711.2 mm
SAE-400 SEVERE DUTY
Displacement
Starting
System
256 cu. in
12VDC batteries
(4.2 L)
(2) & Starter
Bore x Stroke
3.875" x 5.00"
(98.4 mm x 127.0mm)
Volts at Rated Amps
36 volts
40 volts
Auxiliary Power
115/230 VAC
3000 Watts, 60 Hz.
100% Duty Cycle
DEPTH
83.00 in.
2108.2 mm
A-1
Capacities
Fuel: 22.5 gal.
85.1 L
Oil: 8.5 Qts.
8.04 L
Coolant: 3.6 gal.
13.63 L
WEIGHT
2178 lbs.
988.0 kg