Ignition System Wiring - Heat & Glo 6000TRSI-AUC Installation And Operation Instructions Manual

Table of Contents

Advertisement

E. Ignition System Wiring
• This gas heater is equipped with an electronic ignition
system which operates on a 6 volt system.
• This appliance requires 240 VAC to be wired to the
factory installed junction box. Check factory installed
power cord for damage before using.
WARNING
Shock hazard.
• Replace damaged wire with type 105º C
rated wire.
• Wire must have high temperature
insulation.
PILOT
Figure 1.30
20
IGNITION MODULE
6VDC
BATTERY PORT
ON/OFF
SWITCH
GAS LINE
CONNECTED TO
BACK OF VALVE
Heat & Glo • 6000TRSI-AUC • 2078-900 Rev. Q • 6/10
Label all wires prior to disconnection when servicing con-
trols. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.
FLAME SPARKER/
SENSOR
VALVE
REMOTE
CONTROL
ANT.
ON/OFF
WALL SWITCH
IGNITION
MODULE
(6V)
GROUND
NEUTRAL
THERMOCOUPLE
BLOCK
(CONNECTED TO
BACK OF VALVE)
VALVE
CAUTION
HOT
PLUG IN

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents