A-3
LN-10 Connection Instructions
• Turn the Invertec power switch "off".
• Connect the K1505 control cable from the LN-10 to
the Invertec 24/42VAC 14-pin amphenol connector
on the rear of the Invertec.
• Connect the electrode cable to the output terminal
of polarity required by the electrode. Connect the
work lead to the other terminal.
• Set the meter polarity switch on the front of the
Invertec to coincide with wire feeder polarity used.
• See the LN-10 manual for details on accessing
Control DIP Switch
LN-742 Connection Instructions
• Turn the Invertec power switch "off"
• Either a K591 or a K593 Input cable assembly is
required to connect the LN-742 to the Invertec.
• Connect the control cable from the LN-742 to the
24/42 VAC 14-pin wire feeder amphenol on the rear
of the Invertec.
• Connect the electrode cable to the output terminal
of the polarity required by electrode. Connect the
work lead to the other terminal.
• Set the meter polarity switch on the front of the
Invertec to coincide with wire feeder polarity used.
The wire feeder will now display the welding volt-
age.
• If a remote control such as K857 is to be used with
the LN-742, the remote can be connected directly to
the 6pin amphenol on the front of the Invertec or use
a K864 adapter to connect the LN-742 and the
remote to the 24/42VAC 14-pin wire feeder amphe-
nol connector on the rear of the Invertec.
Cobramatic Connection Instructions
• Turn the Invertec power switch "off"
• Connect the control cable from the Cobramatic to
the 24/42 VAC 14-pin wire feeder amphenol on the
rear of the Invertec.
• Connect the electrode cable to the output terminal
of the polarity required by electrode. Connect the
work lead to the other terminal.
• Set the meter polarity switch on the front of the
Invertec to coincide with wire feeder polarity used.
• If a remote control such as K857 is to be used with
the Cobramatic, the remote can be connected
directly to the 6pin amphenol on the front of the
Invertec or use a K864 adapter to connect the
cobramatic and the remote to the 24/42VAC 14-pin
wire feeder amphenol connector on the rear of the
Invertec.
INSTALLATION
TIG MODULE K930-2
The TIG Module connects to the "CE" version with a
K936-1 (9-14 pin) control cable. Connect the K936-1
to the 115VAC Wire Feeder Amphenol on the rear of
the V350-PRO (CE).

CONNECTION OF WIRE FEEDERS TO V350-PRO (CE)

Wire feeders other than LN-7, LN-10 and LN-25 may
be used provided that the auxiliary power supply
capacity of the Invertec is not exceeded. K867
Universal Adapter Plug may be required. See con-
nection diagram S24985 on page F-4.

REMOTE CONTROL OF INVERTEC

Remote Control K857, Hand Amptrol K963 and Foot
Amptrol K870.

UNDERCARRIAGE MOUNTINGS

NOTE: MOUNTING SCREWS CA
0.5 INCHES INSIDE THE MACHINE.
V350-PRO (CE)
MOUNTING HOLE LOCATIONS
N NOT PROTR UDE MORE THAN
3.50
1/4-20 NUT (4 PLACES)
10.00
11.84
M19527
A-3
5.50
8/00