NX-300
Note:
• When using the ESN Validation function of NXDN Trunk-
ing, the NXDN ESN number changes when the circuit
board is changed (the number is written on the circuit
board); the NXDN Trunking System cannot be accessed.
Use the KPG-110SM on the NXDN Trunking System side
to reprogram the NXDN ESN number.
• When a new printed circuit board is used, the Kenwood
ESN changes, as does the Transceiver Information dis-
play of the KPG-111D, but this does not have any effect
on the operation of the transceiver.
• If changing to the original Kenwood ESN and NXDN ESN,
please contact our service center.
Controls
PTT switch
Side1 key
Side2 key
36
TROUBLE SHOOTING
ADJUSTMENT
Selector
Power switch / Volume
Orange key
Universal
connector
Product Number
Label (16 digits)
NXDN ESN
Label (12 digits)
Kenwood ESN Lable
Cut-off Line
Note: A UPC code and UPC barcode is not printed on the
Kenwood ESN Label. If necessary, cut the label at the cut-
off line and attach only the serial number.
Panel Test Mode
■ Test mode operation features
This transceiver has a test mode. To enter test mode,
press and hold the [ ] key while turning the transceiver
power ON. Before the transceiver enters test mode, the
frequency version information appears on the LCD mo-
mentarily. Test mode can be inhibited by programming. To
exit test mode, turn the transceiver power OFF. The follow-
ing functions are available in test mode.