Lincoln Electric IDEALARC SP-250 Service Manual page 52

Lincoln electric welding system user manual
Table of Contents

Advertisement

F-5
TROUBLESHOOTING GUIDE - Observe all Safety Guidelines detailed throughout this manual
PROBLEMS
(SYMPTOMS)
The output voltage and wire feed is
present continuously or pulsing
when gun trigger is NOT activated.
Output settings (voltage and/or wire
feed speed) are being changed even
though gun thumb switch or keypad
keys are not being activated.
No wire feed or open circuit voltage
when gun trigger is pulled. The dis-
play lights up but the audio alarm
and the display do not function prop-
erly.
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, con-
tact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed call 216-
383-2531 or 1-800-833-9353
TROUBLESHOOTING & REPAIR
POSSIBLE AREAS OF
MISADJUSTMENTS(S)
OUTPUT PROBLEMS
1. Remove the gun. If the problem
is resolved the gun trigger circuit
is faulty. Repair or replace.
2. If the problem is not resolved
then contact your Local Lincoln
Electric Authorized Field Service
Facility.
1. Remove the gun. If the problem
is resolved the gun thumb switch
circuit may be faulty. Repair or
replace.
2. If the problem persists after gun
removal then the keypad may be
faulty. Check for burned or dam-
aged areas on the keypad.
1. Check the input voltage at the
machine.
Input voltage must
match the rating plate and the
reconnect panel - High or Low
Line message may be displayed.
2. Remove the gun. If the problem
is resolved the gun is faulty.-
Replace.
CAUTION
IDEALARC SP-250
RECOMMENDED
COURSE OF ACTION
1. Check the machine's internal
trigger leads for grounds or
shorts. See Wiring Diagram.
2. The control board may be faulty.
Replace.
1. Check leads #326 and #327 for
grounds or shorts. See Wiring
Diagram.
2. The Keypad may be faulty.
Perform the Keypad Test.
3. The control board may be faulty.
Replace.
1. Perform the Keypad Test.
2. Perform the Main Transformer
Test.
3. The control board may be faulty.-
Replace.
4. The LCD display may be faulty. -
Replace.
F-5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents