F-35
OUTPUT CAPACITOR BANK NOT FUNCTIONING
This is NOT the typical DC output voltage
waveform. The output capacitors are not
functioning. Note the lack of "filtering" in the
output waveform.
bank was disconnected. Each vertical divi-
sion represents 20 volts and each horizontal
division represents 5 milliseconds in time.
Note: Scope probes connected at machine
output terminals: (+) probe to electrode, (-)
probe to work.
TROUBLESHOOTING & REPAIR
ABNORMAL OPEN CIRCUIT VOLTAGE
The output capacitor
IDEALARC SP-250
SCOPE SETTINGS
Volts/Div . . . . . . . . . . . . . . . . .20 V/Div.
Horizontal Sweep . . . . . . . . . .5 ms/Div.
Coupling . . . . . . . . . . . . . . . . . . . . .DC.
Trigger . . . . . . . . . . . . . . . . . . .Internal.