Theory Of Operation; Theory Of Operation; Input Line Voltage, Fan Motor And Main Transformer - Lincoln Electric SP-100 Service Manual

Lincoln electric welder user manual
Hide thumbs Also See for SP-100:
Table of Contents

Advertisement

E-1
INPUT LINE VOLTAGE, FAN
MOTOR AND MAIN
TRANSFORMER
The 115 vac input power is applied to the
SP-100 through a receptacle located on the
rear panel. The input power is connected to
the fan motor, control board and main
transformer through a line switch located on
the front panel. A circuit breaker is incorpo-
rated in the 115 vac circuit to protect the
unit from current overloads. The fan motor
employs a 24 vac auxiliary winding which
powers the control board. The main trans-
former changes the high voltage, low cur-
rent input power to a low voltage, high cur-
rent output for welding.
NOTE: Unshaded areas of block logic diagram are the subject of discussion.
SP-100

THEORY OF OPERATION

FIGURE E.1 – Input Power Circuits