Lincoln Electric RANGER GXT IM856 Operator's Manual page 18

Lincoln electric welder user manual
Table of Contents

Advertisement

B-2
"
RANGE" SWITCH
The "Range" switch is used to select one of four
amperage ranges with generous overlap for Stick/TIG
welding, or one Wire Feed welding range.
Process
Range Setting
STICK/TIG
80 Max.
(constant current)
130 Max.
(4 range settings)
180 Max.
250 Max.
WIRE FEED
(constant voltage)
14 to 22V
(2 range setting)
18 to 25V
CAUTION
Never change the "RANGE" Switch setting while
welding. This will damage the switch.
------------------------------------------------------------------------
"
CONTROL" DIAL
Provides a fine welding current adjustment within the
Range Switch settings in the STICK mode and weld-
ing voltage control with the Range switch set in the
wire feed mode.
POLARITY SWITCH
Provides three selectable welding polarities:
AC, DC+ & DC-
CAUTION
Never change the Polarity switch setting while
welding. This will damage the switch.
------------------------------------------------------------------------
RANGER GXT APPROXIMATE FUEL CONSUMPTION
Low Idle - No Load
2400 RPM
High Idle - No Load
3700 RPM
AC CC Weld Output
250 Amps @ 25 Volts
DC CC Weld Output
250 Amps @ 25 Volts
DC CV Weld Output
250 Amps @ 25 Volts
Auxiliary Power
10,000 Watts
OPERATION
6-PIN CONNECTOR
For attaching optional remote control equipment.
LOCAL / REMOTE CONTROL SWITCH
(See Accessory Section For "K" numbers)
Current Range
The toggle switch on the control panel labeled
50 to 80 Amps
70 to 130 Amps
"LOCAL" and "REMOTE" provides the option of con-
110 to 180 Amps
trolling the welding output at the control panel or
160 to 250 Amps
remotely. Remote connections are made at the 6-pin
connector. For control at the control panel set the
Up to 250 Amps
switch in the "LOCAL" position.
For remote control set the switch in the "REMOTE"
position.
RANGER GXT
KOHLER
20 H.P. COMMAND
.40 Gallons/Hour
(1.50 Liters/Hour)
.77 Gallons/Hour
(2.91 Liters/Hour)
1.27 Gallons/Hour
(4.82 Liters/Hour)
1.50 Gallons/Hour
(5.09 Liters/Hour)
1.41 Gallons/Hour
(5.33 Liters/Hour)
1.48 Gallons/Hour)
(5.62 Liters/Hour)
B-2