Thank you very much for selecting this new model of Portable Air Conditioner, please read this Use and Care
Manual carefully before installing and using this appliance. Please keep this Use and Care Manual properly for
future reference.
1 / 18

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NPA-10C and is the answer not in the manual?

Questions and answers

Heather E Oakley
May 20, 2025

Where can i get a replacement hose connector that snaps into the back vent and what size is it ?

User image 682c0a7a010c7

Subscribe to Our Youtube Channel

Summary of Contents for Global Air NPA-10C

  • Page 1 Portable Air-conditioner Use and Care Manual Thank you very much for selecting this new model of Portable Air Conditioner, please read this Use and Care Manual carefully before installing and using this appliance. Please keep this Use and Care Manual properly for future reference.
  • Page 2: Safety Instructions

    Safety Instructions 1. Electrical Specifications 1. All wiring must comply with local and national electrical codes and be installed by a qualified electrician. If you have any questions regarding to the following instructions, please contact a qualified electrician. 2. The unit must be installed in accordance with national wiring regulations. Check available power supply and resolve any wiring problems before installation and operation of this unit.
  • Page 3: Function And Technical Specification

    instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision 3.Cautions: ※ Keep the unit at least 1 meter away from TV or radios to avoid electromagnetic interference. ※...
  • Page 4: Technical Specification

    ※ This unit is designed with various protection functions such as 24-hour programmable timer, auto condensate circle, super intelligent temperature sensor and water-full control and warning etc. Technical Specification: Model Unit NPA-10C Power Supply V~,Hz,Ph 110~120,60,1 Cooling Capacity 2.93 Refrigerant/Charge R410A/17.63...
  • Page 5: Installation And Adjustment

    Screws for window kit assembly. 3 total 1. Control panel 14. Wire winding pillar 2. Vertical louvers 15. Back shell 3. Horizontal louvers 16. Power cord 4. Air outlet frame 17. Drain hole and cover 5. Front shell 18. Filter 6.
  • Page 6 1. Installation Warning:  Keep this mobile air-conditioner in an upright position for at least 4 hours before first installation.  Keep the unit in upright position at all times, even when moving to a new location. The air-conditioner should be placed on a flat surface.
  • Page 7  Make sure exhaust hose assembly is securely attached by clips in exhaust outlet to avoid it falling off. 1.3 Installation of window seal-plate Install the rectangle end of exhaust hose adapter into the corresponding rectangle hole in window seal-plate assembly, fix it with screw.
  • Page 8 window frame channel that the window slides in. If necessary mark the kit and cut one end down to properly fit the opening. (Figures D, E, and F) 3. Attach screws to window kit adapter, to hold sliding panels in place. This is for vertical installs only. (Figure K) 4.
  • Page 9: Important Notes

    Move the unit together with its exhaust hose assembly in front of the window and keep the unit at least 50cm away from the walls or other objects. (As Photo). Important notes: The exhaust hose is 280mm-1500mm long. Do not use a different exhaust hose to operate this unit. This unit will only operate properly with the size of the hose provided, and using a different sized hose will affect the performance of the unit.
  • Page 10 1. Control Panel This section explains proper mobile air conditioner operation. Figure 3 On/Off button Up button Mode button Timer button Down button Fan speed button Timer indicator Fan speed indicator Water-full indicator Cool mode Dehumidify mode indicator Fan mode indicator Remote control signal Sleep mode indicator Power indicator...
  • Page 11 Press buttons together to convert Celsius degrees to Fahrenheit degrees and corresponding indicator will light up. Adjust fan speed Press the button to select a desired fan speed shown below Stand-by Press the button again, the unit will stop working with reminding music sounded, will be red in color.
  • Page 12  While the unit is running, Press “Timer” button to set automatic OFF feature, will light up.  Enter the number of hours you would like the unit to run for. The unit will turn off automatically when the set time has elapsed.
  • Page 13: Multiple Protection Functions

    Button: press this button to select “Sleep” function under cooling mode. Before using your remote, install the AAA batteries into remote control. 1. Press and glide the battery cover on the back of the remote control, then you can remove the cover. 2.
  • Page 14: Handling And Transportation

    The compressor motor will turn off when the compressor is running for over 10 minutes and tube temperature inside the compressor is continuously ≦36℉ for 20 seconds while in cooling mode. An error code of E4 will show on the LED display window, and the unit initiates the anti-frost protection. All buttons on control panel (except for power button) are inactive.
  • Page 15: Maintenance And Service

    When the water volume reaches its alarm level in the water tank, a warning will sound and the unit will automatically stop working. The water-full indicator “FL” will be flashing on LED display window. Put a drainage tray or catch pan below the water outlet at the back of the unit. (Tray is not included) Screw off the drain cover, and unplug the water stopper to allow water to flow out of unit into tray.
  • Page 16: End Of Season Storage

    1. Surface cleaning Clean the unit’s surface with a wet soft cloth. Do not use chemical solvents such as alcohol or gasoline to avoid any damage to unit. 2. Filter cleaning Clean the filter every two weeks, otherwise it will affect the performance of the unit, if filter is clogged. 2.1 How to clean filter Grip the filter handle and take it out gently in the correct direction shown by the arrow (as Photo).
  • Page 17: Troubleshooting

    1. Screw off the drain cover, and then pull out the stopper to drain water completely. Note: the tilt angle of the unit must be≦30 2. Keep the unit running in fan mode for 12 hours, to dry inside of unit completely, to prevent unit from going moldy. 3.
  • Page 18 “E4” once anti-freeze protection is over. Water-full indicator lights The water in chassis is full Drain the water and re-start the unit Appendix Fuse parameters Model: FSD or 50F Voltage: 250V Current: 3.15A Schematic diagram of the air conditioner Capillary Condenser Compressor Evaporator...